Dialling Signal Transmission Mode (As Of Sw Version 2.0.2) - Siemens Hicom 100 E Service Manual

Table of Contents

Advertisement

Programming guide
Station attributes
Example: locked telephones are to be authorised to dial the numbers entered in the allowed
numbers list 1.
Input sequence
A
1 4 6
B
+*
C
2
D
<OK>
E
<F8>
A class of service <0> to <4> can be assigned by entering a value (<0>–<14>) under point C.
10.5.4.16

Dialling signal transmission mode (as of SW version 2.0.2)

The trunk line is initially seized if an outgoing external call in "step-by-step" mode is subject to
toll restriction. Dialling is interrupted and the trunk line is released if the extension is not
authorised for the numbers in question.
In "block-by-block" mode, the trunk line is only seized if the extension is authorised to dial the
number in question.
Example: activate "block-by-block" mode
Input sequence
A
1 4 7
B
+*
C
1
D
<OK>
E
<F8>
"Step-by-step" mode can be reactivated by entering "0" under point C.
10-38
Meaning
Code lock
Change input
Enter allowed numbers list 1
Confirm input
Return to Start menu
Meaning
Dialling signal transmission
Change input
Activate block-by-block mode
Confirm input
Return to Start menu
Display
COS: outward restricted
Class of service:
COS: allowed nos. list 1
COS: allowed nos. list 1
System administration
Display
Mode: per digit
Mode:
Mode: en-bloc
Mode: en-bloc
System administration
A31003-K16-X001-3-7620
Hicom 100 E Version 2.1, Service manual
,
07/99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hicom 118Hicom 108Hicom 118-2Hicom 112

Table of Contents