Table of Contents

Advertisement

7.12

Timer

Trunk call pauses
Inter-digit timeout (pseudo end-of-dial)
Code receiver timeout (dial request)
B-tone timeout (release of resources)
Recall timeout
Recall timeout for parked calls
Trunk activation timeout after recall
Call duration for auto. dial using sensors
Activation timeout after auto. dial with sensors
Flash-timeout for consultation hold retrieval
Re-seizure lockout at the end of a trunk call
Door opener timer
Doorbell timer
Activation delay after loop interruption
Seizure delay after loop detection
Flash to trunk
Callback timeout
Camp-on (internal)
Callback duration
Timeout before loop opening (consultation-call prevention BRA) 1s
Loop opening in event of consultation call (BRA only)
Automatic reservation of trunk line (BRA)
Timeout for integrated fax recognition/DTMF DDI
Delay for call duration recording
Display delay
Flash detection time: min. 50ms, max. >
Audible tone receiver detection time, min.
DP pulse/pause relationship
DP inter-digit pause
DTMF transmission time/pause time
NSA pre-hold time
NSA post-hold time
NSA response time
Entries: default value/additional values
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
Timer
Administration and maintenance
Entries
6s/13 s
10s
10s
5s
45s
3min.
60s
configurable
5min.
2s
500ms/2s/6s
3s
30s
400ms
16ms
90ms/270ms
5s
5s
30s
2s
5s
5s
20s
5s
280ms/700ms
50ms
60/40ms/66/33ms
850ms/850ms
90/90ms; NDL 80/80ms
20ms; GBR 240ms
20ms; SPA 30ms
0ms; NDL <300ms
Timer