Installation
Power supply
5.3.4

Battery for UPS2

1 battery box for wall mounting with rechargeable battery and connecting cable (0.4 m) to
the power supply unit
4 wall plugs, 4 woodscrews
Bridging times, see Table 3-27
5.3.5

Installing the battery box

If the UPS (uninterruptible power supply) is required, proceed as follows:
Mount the battery box on the wall, no more than 40 cm from the power supply unit
Connect the cable to the PSU. Check the switch setting!
On = mains/battery operation
Off = mains operation
To system unit
Power cable (rubber connector)
Figure 5-3
Connecting the UPS battery cable
Danger
!
Do not insert the power cable in the mains socket until all installation and connection
work has been completed.
5-4
Mains fuse
UPS
Switch (UPS only) for
mains/battery operation = on
OFF
Mains operation = off
ON
Battery fuse (UPS)
Connecting socket
for battery (UPS only)
A31003-K16-X001-3-7620
Hicom 100 E Version 2.1, Service manual
Pull power supply before
installing system
expansions
,
07/99