Figure 6-6 Call Management (Example, Continued) - Siemens Hicom 100 E Service Manual

Table of Contents

Advertisement

15 = Incoming calls
1519 = Call forwarding
15191 = Call dest. lists
1. 2. 3.
Call dest.
list 1
*
list 2
*
list 3
*
881
.
.
11
.
.
Call dest.
14
list 14
list 15
20
list 16
*
Call Management dests.
Entries:
– = No entry
11–74 = The port assigned to the
number is called
881–888 = Group 1–8 with the
defined call type
= Selected ext. no. of station
*
# = System search operation (as of SW 2.1= #9)
870–873 = Pseudo ports (870=fax; 871=DDI; 872=fax/DDI; 873=announcement before notification)
Figure 6-6
Call Management (example, continued)
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
Block 3
* = Ext. number
dialled
Call first forwarded
to ext. 14
5.
4.
14
881
3
74
11
28
882
5
14
888
3
*1
883
3
883
3
.
.
.
.
.
.
881
10
3
21
3
15 = Incoming calls
15196 = Group setup
881
(group 1)
882
1
(group 2)
2
.
1
.
.
1
.
1
.
888
.
(group 8)
.
2
1
1
Common ringer, mode
15197 =
1 = Called immediately
2 = Called after the first forwarding timeout (column 5)
Common ringer, PEN
15196 =
– = No common ringer
11–74 = The port assigned to the number is called
*1–*4 = Relay option, actuator 1–4
Number of ring attempts
15195 =
No. of ring attempts before call is forwarded(1–15)
Initial operation
Call management (CM)
Block 4
15161 = Ext. called
8 extensions per address
Entries –, 11-74
. . . . .
2
3
4
5
6
1
14 28 72 19
11
12
37
23
.
.
.
12
37
15162 = Call type
1 = Cyclic hunting group
2 = Linear hunting group
3 = Group ringing
7
8
1
3
1
.
.
.
1
6-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hicom 118Hicom 108Hicom 118-2Hicom 112

Table of Contents