6.4

Re-initialising

6.4.1

Re-initialising the system cards (as of SW 2.0.1+)

95
*
Enter code for "System
administration".
The system is returned to its pre-initialisation status with a redefined password. The data
contained in the EEPROM regarding the system configuration is erased, and the configuration
status can be changed as required. Existing customer-specific data is not changed.
If expansion work requiring re-initialisation of the extension number plan is carried out, proceed
as follows:
Enter the re-initialisation password before making the change to ext. 11 > the existing mod-
ule configuration will be erased.
Disconnect the system, release and remove the PSU/UPS, plug in new module(s).
Insert and screw PSU/UPS, connect the system, the extension number plan will be set up
with no gaps as in the case of initial activation.
The extension number plan will be changed, see Extension and line number allocation.
6.4.2

Re-initialising the expansions modules (as of SW 2.0.2)

95
*
Enter code for "System
administration".
Optional modules are automatically recognised when the system is connected and booted.
This data is stored in the EEPROM.
A special password must be entered in order to modify an option that is connected and
recognized. After entering this password and resetting the system, the modules currently
connected are recognized by the system.
Existing messages stored in FAX/DUWA module(s) are erased.
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
62659321
Password for re-initialising
system cards
73855392
Password for re-initialising
modules
Initial operation