10.6.8

ISDN DDI settings

10.6.8.1

Intercept console during the day

In Hicom 100E, ext. 11 is defined as the intercept console by default. All incoming calls during
the day which were not dialled using an extension DDI number but with the console code
(Section 10.6.8.3) are signalled at the intercept console. Moreover, incoming calls which could
not be switched can also be signalled at the intercept console (see "Defining intercept criteria",
Section 10.6.9).
An extension or a call group can be an intercept console during the day.
Since the intercept console during the day is assigned to a call destination list (Section 10.6.4),
the call settings defined in this call destination list are applicable.
Example: extension 12 is to act as the intercept console during the day.
Input sequence
A
1 5 1 3
B
*
C
12
D
<OK>
<F8>
E
A different extension or call group can be programmed as the intercept console during the day
by entering another extension number under point C.
As of SW version 2.0.1+, the following is also applicable:
The intercept console during the day can be cancelled by pressing the F3 key under point C. In
this way, it is possible to assign an individual daytime intercept console to each line (e.g. in the
case of different basic accesses).
Example: ext. 11 is the intercept console during the day for the 1st basic access (line 1 and 2).
Ext. 15 is the intercept console during the day for the 2nd basic access (line 3 and 4).
1.
The actual "intercept console during the day" under code <1513> is deleted, see above.
2.
The required intercept console extensions are assigned to lines 1 to 4.
The assignment is made in CDM 15 17.
Lines in a shared basic access must always be assigned the same intercept console
extension.
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
Meaning
Intercept console during the day
Change input
Select intercept console
Confirm input
Return to Start menu
Programming guide
Station attributes
Display
Ext. no.: 11
Ext. no.:
Ext. no.: 12
Ext. no.: 12
System administration
10-51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hicom 118Hicom 108Hicom 118-2Hicom 112

Table of Contents