Figure 6-8 Example Of Networking - Siemens Hicom 100 E Service Manual

Table of Contents

Advertisement

Initial operation
Networking (Hicom 112/118 only)
Example of extension and line number assignment with networking
(common extension number plan).
Head office
Route 1
Route 2
Route 3
Hicom 300
Internal ext. numbers
4001 - 4299
Figure 6-8
Example of networking
Extension number plan and settings for:
Head office internal numbering 4001–4299
Route 1 > trunk = route code 9, digit repetition deactivated
Route 2 > office A = code 46, digit repetition activated
Route 3 > office B = code 47, digit repetition activated
Office A internal numbering 4611–4632 (can only be set via a PC tool)
Office A: DDI numbering for 11 to 32
Route 1 > trunk = route code 9, digit repetition deactivated
Route 2 > head office = route code 40, 41, 42, 47 digit repetition activated
Office B internal numbering 4711–4732 (can only be set via a PC tool)
Office B: DDI numbering for 11 to 32
Route 1 > head office = route code 0, 40, 41, 42, 46, digit repetition activated
6-18
"9" >
TNK.
"46" >
(CorNet/QSig)
"47" >
(CorNet/QSig)
"9" >
< "40, 41, 42, 47"
Internal ext. numbers
< "0, 40, 41, 42, 46"
Internal ext. numbers
Hicom 100 E Version 2.1, Service manual
Office A
Route 1
Route 2
Hicom 112/118
4611–4632
Office B
Route 1
Hicom 112/118
4711–4732
A31003-K16-X001-3-7620
,
07/99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hicom 118Hicom 108Hicom 118-2Hicom 112

Table of Contents