10.2.2

Setting a dial pause

It may be necessary to insert a pause before transmitting the dialling signal at analogue
attendant consoles (e.g. if there is a delay in the ready-to-record-digit status at the attendant
console). The pause can be defined for each route.
Example: a 3-second pause is to be observed between line seizure and transmitting the
dialling signal to route 1 lines.
Input sequence
A
202
B
*
C
2
D
<OK>
E
<F8>
If necessary, other pause durations can be set by entering other values under point C. The
following values are possible:
0 = no pause, 1= 1 s, 2 = 3 s, 3 = 6 s, 4 = 9 s
10.2.3

Changing a trunk call interval

The trunk call interval must be increased to 13 seconds for Hicom 100E if the system is
connected to analogue attendant consoles with 10-second ringing. The interval duration can
be defined for each route.
Input sequence
A
203
B
*
C
2
D
<OK>
E
<F8>
The trunk call interval can be reset to 6 by entering "1" under point C.
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
Meaning
Dial pause for route 1
(select route 2–4 with "+" and "–" or
directly with "#")
Change input
Pause = 3 seconds
Confirm input
Return to Start menu
Meaning
Trunk call interval for route 1
(select route 1- 4 with "+" and "–" or
directly with "#")
Change input
Trunk call interval = 13 seconds
Confirm input
Return to Start menu
Programming guide
Analogue trunk
Display
Route 1: no pause
Route 1
Route 1: 3 s
Route 1: 3 s
System administration
Display
Route 1: 6 s
Route 1
Route 1: 13 s
Route 1: 13 s
System administration
10-5