10.3.6

Route type

Each of the 4 possible routes can be defined either as "trunk" line types (default) or as "PBX"
line types.
In the case of the "trunk" line type, Hicom 100E checks for the (continuous) dial tone before
transmitting the dialling signal. A flash pulse is transmitted for 300 ms.
In the case of the "PBX" line type, the system does not check for a dial tone. Toll restriction is
only implemented if the trunk code of the main PBX is entered for the route in question. A flash
pulse is transmitted for 80 ms.
Example: change the line type of route 2 from "trunk" to "PBX"
Input sequence
A
1 6 4 (up to
SW2.0.2)
1 6 14(as of SW2.1)
B
+
C
*
D
1
E
<OK>
F
<F8>
The "trunk" line type can be programmed by entering "0" under point D.
10-12
Meaning
Line type of route 1
(select route 1–4 with "+" and "–" or
directly with "#")
Scroll to route 2
Change input
Line type route 2 = PBX
Confirm input
Return to Start menu
Display
Route 1: trunk
Route 2: trunk
Route 2:
Route 2: PBX
Route 2: PBX
System administration
A31003-K16-X001-3-7620
Hicom 100 E Version 2.1, Service manual
,
07/99