Allocating Extensions And Actuators - Siemens Hicom 100 E Service Manual

Table of Contents

Advertisement

Example: the response time for actuator 1 is to be set to 5 seconds – value to be entered is 50.
Input sequence
A
2 5 2
*
B
C
50
D
<OK>
E
<F8>
A different response time can be defined by entering another value under point C.
10.8.1.3

Allocating extensions and actuators

An extension must be allocated in the case of actuators 5 and 8.
The entrance telephone must be allocated in the case of actuator 4.
The other actuator types can be activated from all extensions (no ext. no. assigned) or from one
extension or the members of a call group (ext. or group no. assigned).
Example: it should be possible for members of call group 883 to activate actuator 1.
Input sequence
A
2 5 3
*
B
C
883
D
<OK>
E
<F8>
An assigned extension can be deleted by pressing the F3 key under point C.
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
Meaning
Actuator response time
(select actuator 1–4 with "+" and "–" or
directly with "#")
Change input
Select response time factor
Confirm input
Return to Start menu
Meaning
Ext. assigned for each actuator
(select actuator 1–4 with "+" and "–" or
directly with "#")
Change input
Select ext. number
Confirm input
Return to Start menu
Programming guide
Programming expansion modules
Display
Actuator no. 1: 255
Actuator no. 1:
Actuator no. 1: 50
Actuator no. 1: 50
System administration
Display
Actuator no. 1: –
Actuator no. 1:
Actuator no. 1: 883
Actuator no. 1: 883
System administration
10-77