HEAT EXCHANGER
INSPECTION
1. Inspect:
S Coolant hoses
S Heat exchangers
S Oil cooler
S Coolant pipes
Cracks/damage ! Replace.
2. Measure:
S Filler cap opening pressure
Cap opens with a pressure below the speci-
fied pressure ! Replace.
Filler cap opening pressure:
95 X 125 kPa
(0.95 X 1.25 kg/cm
14 X 18 psi)
Measurement steps:
S Attach the cooling system tester 1 to the cool-
ant filler cap 2 .
Cooling system tester:
90890-01325, YU-24460-01
Adapter:
90890-01352, YU-33984
S Apply the specified pressure for 10 seconds
and make sure there is no pressure drop.
6-3