Yamaha 2006 RX10GTAXW Service Manual page 1203

Table of Contents

Advertisement

TROUBLESHOOTING
1. Connect:
S Pocket tester
(to the battery terminals)
2. Measure:
S Battery voltage
Battery voltage:
more than 12 V at 20_C (68_F)
3. Start the engine and accelerate to 5,000
r/min.
4. Measure:
S Charging voltage
Charging voltage:
14 V/5,000 r/min
WARNING
Be sure the V-belt is removed.
CAUTION:
Never disconnect battery cables while
generator is operating, otherwise, the rec-
tifier/regulator will be damaged.
Correct connecter.
BATTERY IS NOT CHARGED.
OK
OK
CHARGING SYSTEM
OUT OF SPECIFICATIONS
S Check the battery.
S Replace and/or charge the battery.
Refer to "BATTERY INSPECTION" in
CHAPTER 2.
OUT OF SPECIFICATION
S Check the main fuse.
Refer to "FUSE INSPECTION" in CHAP-
TER 2.
S Check the startor coil.
OK
Replace the main fuse, recti-
fier/regulator
startor coil assembly.
Replace the rectifier/regulator.
8-17
ELEC
FAULTY
and/or
the