Hitachi GR2000 Series Configuration Commands page 130

Hitachi gigabit router configuration guide
Hide thumbs Also See for GR2000 Series:
Table of Contents

Advertisement

Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2
Table 1-47 Operating Parameters that Can Be Set for Each Operation
Operation Parameter
Priority designation by input IP packet
DSCP
-dscp_map
Contract band monitoring
-penalty_drop
Decision of priority by using DSCP of
input IP packet.
-penalty_discard <No.>
Abortion at contract band breach.
-penalty_dscp <DSCP_Value>
Output VC and DLCI designation
-index <Value>
:
Indispensable
x:
Can be set, and default. No mark: Setting is impossible.
*1:
This is the operating parameter of contract band monitoring. These conditions cannot be set when
"-min_rate<kbps>[-min_rate_burst<Byte>]" is specified. To guarantee the minimum band, this parameter can only
change the queuing priority of a packet that violates the contract band.
*2:
This is the operating parameter of contract band monitoring. These conditions cannot be set when only
"-max_rate<kbps> [-max_rate_burst<Byte>]" is specified. To limit the maximum band, this parameter can only discard
a packet that violates the contract band.
*3:
This is the operating parameter of contract band monitoring. Omit these conditions when
"-max_rate<kbps>[-max_rate_burst<Byte>]" is specified.
*4:
This is the operating parameter of contract band monitoring. The operation of a packet that violates the contract
band of "-min_rate<kbps>" is specified when "-max_rate<kbps>[-max_rate_burst<Byte>]
-min_rate<kbps>[min_rate_burst<Byte>]" is specified.
*5:
No setting is possible on the VLAN line.
*6:
Only VLAN lines can be set. In addition, output priority determination and DSCP rewrite cannot be set
simultaneously.
Description:
Default:
Description:
Default:
Description:
Default:
Description:
1-88
1
2(*1) 3(*2)
4
x (*3)
x
x
x
Specifies the subject interface name set in the ip information
or ip-address information. (The ip information or the
ip-address information should be set before inputting this
command.) RM Ethernet and Tunnel interface are not
supported. For details, refer to Table 1-5.
No default is possible.
Specifies the Inbound/Outbound. Either one or both of the
Inbound/Outbound can be set against one interface.
in: Inbound (specification of the frame input side)
out: Outbound (specification of the frame output side)
No default is possible.
Nullifies the flow control by input/output interface.
Flow control is executed.
Specifies the list number.
Flow Control
5(*1) 6(*2)
7
x (*3)
x (*3)
x
x
x
x
8(*1) 9(*2)
10
11
x
x
GR2K-GA-0014
Ver. 07-02

Advertisement

Table of Contents
loading

Table of Contents