TX Power Low
Warning threshold
Power Low Warning
threshold
Temperature
Voltage
Tx Bias Current
Tx Power
Rx Power
Data Ready state
Bar
Rx LOS state
Tx Fault state
Rate Select state
RS state
Tx Disable state
Temperature High
Alarm Flag
Voltage High Alarm
Flag
Tx Bias High Alarm
Flag
742
Description
Factory-defined setting. Value can differ between SFP and SFP+.
Factory-defined setting. Value can differ between SFP and SFP+.
Current temperature of the sfps. If this temperature crosses Temp
High alarm/warning thresholds, the temperature high alarm/warning
flag is set to true.
Current voltage of the sfps. If this voltage crosses voltage high
alarm/warning thresholds, the voltage high alarm/warning flag is set
to true.
Present Tx bias current of the SFP. If this crosses bias high alarm/
warning thresholds, the tx bias high alarm/warning flag is set to true.
If it falls below the low alarm/warning thresholds, the tx bias low
alarm/warning flag is set to true.
Present Tx power of the SFP. If this crosses Tx power alarm/warning
thresholds, the Tx power high alarm/warning flag is set to true. If it
falls below the low alarm/warning thresholds, the Tx power low
alarm/ warning flag is set to true.
Present Rx power of the SFP. This value is either average Rx power
or OMA. This depends on the Rx Power measurement type displayed
above. If this crosses Rx power alarm/warning thresholds, the Rx
power high alarm/warning flag is set to true. If it falls below the low
alarm/warning thresholds, the Rx power low alarm/warning flag is
set to true.
This field indicates that the transceiver has achieved power up and
data is ready. This is set to true if data is ready to be sent and set to
false if data is being transmitted.
This is the digital state of the Rx_LOS output pin. This is set to true if
the operating status is down.
This is the digital state of the Tx Fault output pin.
This is the digital state of the SFP rate_select input pin.
This is the reserved digital state of the pin AS(1) per SFF-8079 and
RS(1) per SFF-8431.
If the admin status of the port is down then this flag is set to true.
This can be either true or false, depending on the Current voltage
value displayed above.
This can be either true or false, depending on the Current
Temperature value displayed above.
This can be either true or false, depending on the present TX bias
current value displayed above.