Mac Access-List Standard - Dell Force10 Z9000 Reference Manual

Ftos command line reference guide for the z9000 system ftos 9.1.(0.0)
Hide thumbs Also See for Force10 Z9000:
Table of Contents

Advertisement

mac-source-
address
mac-source-
address-mask
count
byte
log
monitor
Defaults
Not enabled.
Command Modes
CONFIGURATION-MAC ACCESS LIST-STANDARD
Command History
Version 8.3.11.1
Version 8.1.1.0
Version 7.6.1.0
Version 7.5.1.0
Version 7.4.1.0
Usage
When you use the log option, the CP processor logs detail the packets that match. Depending
Information
on how many packets match the log entry and at what rate, the CP may become busy as it has
to log these packets' details.
Related
permit
Commands
seq

mac access-list standard

Name a new or existing MAC access control list (MAC ACL) and enter MAC ACCESS LIST mode to configure a standard
MAC ACL. Also refer to the Commands Common to all ACL Types section and the Common MAC Access List Commands
section.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
mac access-list standard mac-list-name
266
Enter a MAC address in nn:nn:nn:nn:nn:nn format.
(OPTIONAL) Specify which bits in the MAC address must match. If no
mask is specified, a mask of 00:00:00:00:00:00 is applied (in other
words, the filter allows only MAC addresses that match).
(OPTIONAL) Enter the keyword count to count packets processed
by the filter.
(OPTIONAL) Enter the keyword byte to count bytes processed by
the filter.
(OPTIONAL, E-Series only) Enter the keyword log to log the packets.
(OPTIONAL) Enter the keyword monitor when the rule is describing
the traffic that you want to monitor and the ACL in which you are
creating the rule is applied to the monitored interface. For more
information, refer to the "Flow-based Monitoring" section in the Port
Monitoring chapter of the
Introduced on the Z9000.
Introduced on the E-Series ExaScale.
Introduced on the S-Series.
Introduced on the C-Series.
Added the monitor option.
NOTE: When ACL logging and byte counters are configured simultaneously, byte counters
may display an incorrect value. Configure packet counters with logging instead.
– configures a MAC address filter to pass packets.
– configures a MAC address filter with a specified sequence number.
FTOS Configuration Guide .

Advertisement

Table of Contents
loading

Table of Contents