Version 8.3.1.0
Usage
The running router sets the remaining time value to the current adjacency hold time. You can
Information
override this setting by implementing this command.
Override the default restart-wait time by entering the no graceful-restart
restart-wait command. When you disable restart-wait, the current adjacency hold
time is used.
Set the t3 timer to adjacency on the restarting router when implementing this command. The
restarting router gets the remaining time value from its peer and adjusts its T3 value so only
when you have configured graceful-restart t3 adjacency.
Related
graceful-restart restart-wait
Commands
restarting peer comes up.
graceful-restart restart-wait
Enable the graceful restart maximum wait time before a restarting peer comes up.
E-Series, S4810
Syntax
graceful-restart restart-wait seconds
To return to the default, use the no graceful-restart restart-wait command.
Parameters
seconds
Defaults
30 seconds
Command Modes
ROUTER ISIS
Command History
Version 8.3.12.0
Version 8.3.1.0
Related
graceful-restart t3
Commands
Introduced on the E-Series.
– enables the graceful restart maximum wait time before a
NOTE: Set the t3 timer to adjacency on the restarting router when implementing this
command.
Enter the graceful restart time in seconds. The range is 5 to 300
seconds. The default is 30 seconds.
Introduced on the S4810.
Introduced on the E-Series.
– configures the overall wait time before graceful restart completes.