show ip ospf interface

Display the OSPF interfaces configured. If OSPF is not enabled on the switch, no output is generated.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
show ip ospf process-id interface [interface]
Parameters
process-id
interface
Command Modes
Command History
Version 8.3.11.1
Version 8.3.7.0
Version 7.8.1.0
Version 7.6.1.0
Version 7.5.1.0
pre-Version
6.1.1.1
Enter the OSPF Process ID to show a specific process. If no Process
ID is entered, command applies only to the first OSPF process.
(OPTIONAL) Enter the following keywords and slot/port or number
information:
EXEC
EXEC Privilege
Introduced on the Z9000.
Introduced on the S4810.
Added support for Multi-Process OSPF.
Introduced on the S-Series.
Introduced on the C-Series.
Introduced on the E-Series.
For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed by the slot/port information.
For the null interface, enter the keyword null followed by
zero (0).
For loopback interfaces, enter the keyword loopback
followed by a number from 0 to 16383.
For Port Channel groups, enter the keywords port-
channel followed by a number. For the C-Series and S-
Series, the range is 1 to 128. For the E-Series, the range is 1 to
255 for TeraScale.
For a SONET interface, enter the keyword sonet followed by
the slot/port information.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet followed by the slot/port
information.
For a VLAN, enter the keyword vlan followed by the VLAN
ID. The range is from 1 to 4094.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE followed by the slot/port information.