Manual Transmission
Secondary Shaft Inspection (cont'd)
lnspect for runout by supporting both ends of
secondary shaft. Rotate the secondary shaft two
complete revolutions when measuring the runout.
lf the runout is more than the service limit, replace
the secondary shaft with a new one.
Standard: 0.02 mm (0.001 in.) max.
Service Limit: 0.05 mm {0.002 in.l
Rotate two complete
revolutions.
13-46
Secondary Shaft Reassembly
Special Tools Requir€d
. Attachment. 45 mm 07947-6890300
. Bearing attachment 07LAD-PW50601
' 1 .
I n s t a l l t h e t a p e r e d r o l l e r b e a r i n g s u s i n g t h e s p e c i a l
tool and a Dress as shown,
-6890300
07LAD-PWs0601