Audio System
J
J
1 .
Radio Remote Switch Test
Remove the instrument panel (see page 20-80).
Disconnect the 6P connector (A) from the switch.
Remove the three mounting screws (B).
Measure resistance between the No. 5 and No.6
terminals in each switch position according to the
table.
lf the resistance is not as specified, replace the
switch.
t
3.
4 .
Position
Resistance
O F F
Aoorox. 10 k Q
V O L . U P
( + )
Approx. 307.3 k Q
VOL, DOWN
( )
Approx.46.8 k Q
CH
A D D r o x . 9 0 6 . 6 k Q
MODE
Aoorox. 2.6 k O
22-90
I
5. Check for continuity between the terminals in each
switch position according to the table.
lf the continuity is not as specified, replace the
illumination bulb{s) (B) or the switch.
\
Terminal
t ""-
-----
----\
3
1
COMBINATION LIGHT SWITCH ON
G
o
COMBINATION LIGHT SWITCH OFF
With the MUTE switch ON, check for continuity
between the No.2 (+) and No. 1 ( ) terminals.
There should be continuity. lf there is no continuity,
reolace the switch.