336
Chapter 25 Replacing or installing a cooling fan

Installing an expansion unit fan

Warning: Protect the hardware components against damage from electrostatic discharge.
Always wear a grounded wrist strap before you handle components. Always place the
components in a static-free container.
Note: Ensure the label of the new fan faces the back wall of the BCM expansion unit
chassis. Airflow is out of the chassis as indicated by the arrows imprinted on the fan.

To install an expansion unit fan

1
Place the fan in the expansion unit so that the label faces the back wall of the unit.
2
Align the screw holes in the fan with the screw holes in the expansion unit and attach the fan.
3
Connect the fan power supply cable to the hub board.
4
Replace the cover.
5
Restore the BCM system to operation. For details, refer to
maintenance" on page
The BCM system starts up when you connect the AC power cord. The start-up process takes
several minutes to complete.
6
Test the direction of the fan exhaust air flow to determine if the fan is correctly installed.
a
Hold a piece of paper or your hand close to the fan exhaust. A correctly installed fan blows
air away from the main unit.
b If the fan exhaust air flow is incorrect, remove the cooling fan (see
cooling fan" on page

Troubleshooting cooling fans

There are three LEDs on the front of the BCM base function tray and one on the front of the
expansion unit used to assess fan functionality.
and temperature LEDs.
Table 84 Fan and temperature LEDs on the base function tray
LED Label Description
Temperature
Fans
Power
N0060612
N0060612
234.
331) and reinstall the fan in the correct orientation (this procedure).
Table 84
Green LED On
Temperature is below
threshold.
All installed fans are working.
All components are working.
"Restarting the system after
"Removing a BCM200
describes the possible states of the fan
Red LED On (Only)
Temperature is in alarm status.
Possible fans failure.
There is a problem with a minimum of
one fan.
Component failure.

Hide quick links: