Changing Configurations - Nortel BCM200 Installation And Maintenance Manual

Business communications manager
Hide thumbs Also See for BCM200:
Table of Contents

Advertisement

156
Chapter 9 Connecting the cables
Table 56 Three BRI modules, two DSM 32s, and one DECT module
DS30
channel #
2
3
4
5
0
6
7

Changing configurations

Here are some points to consider when changing modules in existing or new BCM systems:
Trunk and analog station MBMs cannot share a DS30 bus.
MBMs that require more than one DS30 bus automatically assign the next bus in
chronological order. Therefore, if an existing installed MBM uses either of the required DS30
buses, remove the installed MBM. You must then assign the DIP switches for both MBMs so
there is no conflict between them or with any other installed MBM.
N0060612
N0060612
Each heavily-outlined and shaded square
represents one module
1
3
DECT
BRI
offset 0
offset 0, 1 and 2
DECT switch settings:
0
1
2
Switch setting
2
DSM32s
offset 0
1
2
3
0
on on on on on on
0
on on on on off on
on on off on on on
BRI settings on on on off on off
BRI settings on on off off on off
BRI settings on off on off on off
4
5
6