Nortel BCM200 Installation And Maintenance Manual page 132

Business communications manager
Hide thumbs Also See for BCM200:
Table of Contents

Advertisement

132
Chapter 8 Installing a media bay module (MBM)
Table 43 DSM16/DSM16+ and DSM32/DSM32+ single-density switch settings (upgraded system)
Enter these switch
Select
settings
DS30
bus
1
2
3
on
on
on
2
on
on
on
3
on
on
on
4
on
on
on
5
on
on
on
6
on
on
on
***7
**The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a
different Start DN, enter the range in the blank column.
***If your system is configured with a 3/5 DS30 split, you cannot use DS30 7 for the DSM 16 module. You cannot
configure the DSM 32 module for DS30 6 because the second set of DNs cannot be accessed.
DSM16+ and DSM 32+ double density switch settings (upgraded system)
The following table shows the switch settings for DSM-plus modules deployed as double density
on a system that has been upgraded from BCM 2.5 to BCM 3.0 or later software.
Note: DSM modules deployed with BCM 2.5 systems are all single density and cannot be
set to double density. The DSM 16+ and DSM32+ modules can be set to either density.
Table 44 DSM 16+ and DSM32+ double density switch settings (upgraded system)
Select
Enter these switch settings
DS30
bus
1
2
off
on
2
off
on
off
on
3
off
on
off
on
4
off
on
off
on
5
off
on
off
on
6
off
on
off
on
**7
off
on
* The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a
different Start DN, enter the range in the blank column.
** If your system is configured with a 3/5 split, you cannot use DS30 7 for the DSM 16 module.
N0060612
N0060612
4
5
6
on on on
on on off
on off on
on off off
off on on
off on off
3
4
5
6
on
on
on
on
A
off
on
on
on
B
on
on
on
off
A
off
on
on
off
B
on
on
off
on
A
off
on
off
on
B
on
on
off
off
A
off
on
off
off
B
on
off
on
on
A
off
off
on
on
B
on
off
on
off
A
off
off
on
off
B
**To assign these
DNs to
DSM16 or
DSM 16+
221-236
237-252
253-268
269-284
285-300
301-316
*To assign these DNs
to
DSM 16+:
(A= DSM1, B=DSM2)
221-236
377-392
237-252
393-408
253-268
409-424
269-284
425-440
285-300
441-456
301-316
457-472
To assign these DNs to
DSM 32 or DSM 32+
221-252 (DS30 2 and 3)
237-268 (DS30 3 and 4)
253-284) (DS30 4 and 5)
269-300 (DS30 5 and 6)
285-316 (DS30 6 and 7)
N/A
To assign these DNs to
DSM 32+
(connectors: A=top,
A
377-392
B
A
393-408
B
A
409-424
B
A
425-440
B
A
441-456
B
A
457-472
B
B = bottom)
221-236
237-252
253-268
269-284
285-300
301-316

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcm400

Table of Contents