Figure 157 Remove the redundant power supply cage and support bracket
14 Cut the cable ties that hold the power cables to the power supply support bracket. Be careful
not to cut or damage the cable insulation.

Installing a power supply module

This procedure describes how to install power supply modules in the power supply cage. After you
install the redundant power supply cage in the main unit, insert the two power supply modules.
Use this procedure also to replace faulty power supply modules. Redundant power supply modules
can be exchanged while the system is running, as long as one of the modules remains active. This
section is relevant only with the BCM400 main unit.
Note: When you upgrade to a redundant power supply, you must also install a redundant
fan. Refer to
Warning: Protect the hardware components against damage from electrostatic discharge.
Always wear a grounded wrist strap before you handle components. Always place the
components in a static-free container.

To install a power supply module

1
Ensure you have the correct redundant power supply cage installed in the BCM400 main unit
(see
"Installing a redundant power supply cage (BCM400 only)" on page
2
Ensure that you position the power supply modules correctly before inserting them into the
power supply cage. The green LEDs are located at the top right of the power supply modules.
Unfasten the power supply
support bracket (power
1
supply not shown)
"Installing a BCM400 cooling fan" on page
Chapter 23 Replacing or upgrading a power supply
BCM200/400 4.0 Installation and Maintenance Guide
Remove the power
2
supply and support
bracket from main unit
3
Cut the cable tie-wrap
away from the power
supply support bracket.
Remove power supply
328.
290).
297