Upgrading To A Redundant Power Supply - Nortel BCM200 Installation And Maintenance Manual

Business communications manager
Hide thumbs Also See for BCM200:
Table of Contents

Advertisement

288
Chapter 23 Replacing or upgrading a power supply
Figure 147 Fasten the standard power supply to the main unit
Fasten power
supply mounting
screws
10 Attach the 20-pin motherboard connector and the +12V power connector into the I/O card.
11 Route the power cable, auxiliary, and IDE cables to the hard disk cage. Bundle the cables
together and fasten to the roof of the main unit using the cable clamp (see
12 Connect the power cable and IDE cable to the hard disk.
13 Run the auxiliary cable to the chassis cable slot (see the next step).
14 Connect cable runs P2 and P3 to the media bay backplane as follows.
a
Connect cable P2 into the bottom media bay module backplane power connector.
b Connect cable P3 into the top media bay module backplane connector.
c
Bundle power cables P2 and P3 along with auxiliary cable (P7 or P8) together with a
grommet (see
d Insert the P2, P3, and auxiliary cable into the cable slot on the chassis (secured with the
grommet).

Upgrading to a redundant power supply

Use the procedures in this section to upgrade a BCM400 main unit, currently equipped with a
standard power supply, with a redundant power supply. This section contains the following
procedures:
"Removing the PSU status connector jumper" on page 289
"Installing a redundant power supply cage (BCM400 only)" on page 290
N0060612
N0060612
Figure
155).
Fasten power,
auxiliary, IDE
cables using
cable clamp -
located on
underside of
cover
Figure
147).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcm400

Table of Contents