To Access Disk Mirroring; Accessing Disk Mirroring Through Element Manager - Nortel BCM200 Installation And Maintenance Manual

Business communications manager
Hide thumbs Also See for BCM200:
Table of Contents

Advertisement

Accessing disk mirroring through Element Manager

Use this procedure to review the primary master and mirror master hard disk settings on systems
equipped with a RAID configuration. Use Element Manager in this procedure to monitor the
RAID disk mirror operation.
Note: You must ensure the system status monitor service is running to monitor primary
master and mirror master disk operation and disk mirroring activity.

To access disk mirroring

1
Access Element Manager after system bootup is complete.
2
From the Administration tab, click System Status, and then click Disk Mirroring.
The Disk Mirroring screen displays (see
3
In the Settings area, ensure the following fields display the default values as shown (see
Table
81):
a
Operation Mode = Mirror Mode
b Beep on drive failure = Every 30 seconds (you can configure the interval between beeps).
Note: On some systems, if the RAID card fails, the audible alarm sounds continuously for
15 seconds. After the 15 second period, the beep alarm sounds in accordance to the beep
timing setting.
Chapter 19 System monitoring and troubleshooting
Figure
104).
BCM200/400 4.0 Installation and Maintenance Guide
225