DSM16/DSM 32 single density switch settings (new system)
The following table shows the switch settings for DSM modules deployed as single density on a
new system running BCM 3.0 or later software.
Note: DSM modules deployed prior to BCM 3.0 are all single density and cannot be set to
double density, but they can still be used on new systems. The DSM 16+ and DSM32+
modules can be set to either density.
Table 45 DSM16/DSM16+ and DSM32/DSM32+ single density switch settings (new system)
Enter these switch
Select
settings
DS30
bus
1
2
3
on
on
on
2
on
on
on
3
on
on
on
4
on
on
on
5
on
on
on
6
on
on
on
**7
* The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a
different Start DN, enter the range in the blank column.
**If your system is configured with a 3/5 split, you cannot use DS30 7 for the DSM 16 module. You cannot configure
the DSM32 module for DS30 6 because the second set of DNs cannot be accessed.
DSM16+ and DSM 32+ double density switch settings (new system)
The following table shows the switch settings for DSM-plus modules deployed as double density
on a new system (BCM 3.0 or later software).
Note: DSM modules deployed prior to BCM 3.0 are all single density and cannot be set to
double density, but they can still be used on new systems. The DSM 16+ and DSM32+
modules can be set to either density.
Table 46 DSM 16+ and DSM32+ double density switch settings (new system) (Sheet 1 of 2)
Enter these switch settings
Select
DS30
bus
1
2
off
on
2
off
on
off
on
3
off
on
off
on
4
off
on
*To assign these DNs to
4
5
6
on
on
on
on
on
off
on
off
on
on
off
off
off
on
on
off
on
off
3
4
5
6
on
on
on
on
A
off
on
on
on
B
on
on
on
off
A
off
on
on
off
B
on
on
off
on
A
off
on
off
on
B
Chapter 8 Installing a media bay module (MBM)
DSM 16 or DSM 16+
221-236
253-268
285-300
317-332
349-364
381-396
To assign these
DNs
to
DSM 16+:
A= DSM1, B=DSM2
221-236
237-252
253-268
269-284
285-300
301-316
BCM200/400 4.0 Installation and Maintenance Guide
To assign these DNs to
DSM 32 or
DSM 32+
Top
Bottom
253-268 221-236
285-300
253-268
317-332 285-300
349-364 317-332
381-396
349-364
N/A
To assign these DNs to
DSM 32+ (connectors:
A=top, B = bottom)
A
237-252
B
221-236
A
269-284
B
253-268
A
301-316
B
285-300