Checking system power and status

After you connect power to the BCM system, the Power LED on the front of the base function tray
and expansion unit lights. Once the system services have reactivated, the Power and Status LEDs
turn solid green. For further information on LED indicators, see
on page
77.
LEDs in position 3 to 8 will flash when the SSM is not communicating (during startup, shutdown,
or operating system hang).
Note: During system initialization, the system performs diagnostics on the hardware
configuration size and installation. If the power fails, system data remains in memory.

To check system power and status

1
If the base function tray Power LED does not light:
a
Disconnect the power cords.
b Check all cables and power connections.
c
Ensure that the AC outlet has power.
d Reconnect the power cords.
If the Power LED still does not light, then you have a faulty power supply module. For details
on replacing a power supply module, see
277.
2
If the Power LED is red, then the system generated a critical or major alarm. To resolve an
alarm condition, see
3
You are now ready to connect the system to the network and initialize it.
Note: You can monitor the state of the BCM system LEDs from your computer.
When the system power is on, and the system has successfully booted, the Power and Status LEDs
on the faceplates of the MBM are lit and remain constant.
and the LEDs on the MBM faceplate.
Status LED states.
"Replacing or upgrading a power supply" on page
"Resolving alarm conditions" on page
Table 48
BCM200/400 4.0 Installation and Maintenance Guide
Chapter 9 Connecting the cables
"Viewing the BCM system LEDs"
219.
Figure 75
shows an example of an MBM
provides a description of the MBM Power and