Chapter 9 Connecting the cables

Connect the MBMs to service providers

To connect DTM, CTM, CTM8, BRIM S/T, or 4x16 MBMs

1
On the front of the MBM, locate the RJ-48C jack (DTM), RJ-45 jack (BRIM), or the RJ-11
jacks (CTM and 4x16).
2
Wire one end of the cable to the demarcation blocks of the building.
Figure 76
shows the wiring pin-outs for a DTM to connect to a service provider.
Figure 76 DTM RJ-48C wiring array
DTM connector
Warning: If you are using a service provider channel service unit (CSU), you must
disable the BCM system internal CSU.
Figure 77
shows the wiring pin-out for a CTM4, a CTM8, or the CTM jacks on a 4x16 MBM
to connect to the service provider.
All the MBMs have an auxiliary jack (the CTM8 has two). Do not attempt to plug digital
equipment into this jack.
Figure 77 CTM RJ-11 wiring array
CTM
connector
N0060612
N0060612
RJ-48C jack
1 2 3 4 5 6 7 8
Auxiliary jack
6 5 4 3 2 1
To network
Receive from
network
Transmit to network
Pin #/connection
RJ-11 jacks
The CTM8 has ten RJ-11 jacks, including two
auxiliary jacks.
The 4x16 and CTM4 MBMs have four RJ-11 jacks.
To plug
1- Rring
2 - Rtip
3 - Rshield
4-Tring
5-Ttip
6-Tshield
3- Ring
4 - Tip