Combining CTMs/GATMs and 4x16s

The 4x16 combination MBM is a combination of a CTM4 and a DSM16. A maximum of four
CTM4s/GATM4s can fit into a DS30 bus when each is given a different offset. Therefore, you can
combine a maximum of three CTM4s/GATM4s with a 4x16 MBM. This configuration would
occupy two full DS30 buses.
You can install a maximum of three of the above combinations in a BCM system with an
expansion unit added to it.
including the switch settings for each MBM.
Table 53 CTMs/GATMs combined with 4x16 MBMs
Each heavily-outlined and shaded square represents
DS30 #
4x16s
offset 3
2
3
3
4
3
5

Fully-loaded setup

This section describes a system containing one DSM 32/32+, one DSM 16/16+, two ASM 8s, and
two DTMs. This configuration uses all the DS30 buses, with the exception of two offsets.
Table 53
demonstrates this configuration of CTMs and 4x16 MBMs,
one module
2
4
CTM4s/GATM4s
offset 0, 1 and 2
0
1
2
Switch settings for 4x16:
0
Switch settings for 4x16:
Chapter 9 Connecting the cables
1
CTM8/GATM8
offset 2
CTM/GATM settings:
CTM/GATM settings:
CTM/GATM settings:
CTM/GATM settings:
2
BCM200/400 4.0 Installation and Maintenance Guide
Switch setting
1
2
3
4
5
6
on on on on on on
on on off on on on
on off on on on on
on off off on on on
on on on on off on
on on off on off on
on off on on off on
on off off on off on
153