174
Chapter 11 Installing the analog terminal adapter
•
Replace the analog telephone with the test set.
•
Use TRANSMIT/600 OHM/HOLD mode on the test set.
3
Make sure the test set connects in parallel to the service line before removing the analog
telephone or the line drops.
4
Remove the analog telephone.
5
Introduce a 1 kHz tone into the analog line at - 10 dBm, and measure the level at the CO
exchange.
Note: The difference in levels is the transmit loss and must be less than 10 dB
(for example, 9 dB is acceptable).
Configuring the ATA2
Configure the ATA2 using Element Manager or Telset Administration. For detailed configuration
information, refer to the BCM 4.0 Device Configuration Guide.
N0060612
N0060612