Asm 8 And Gasm8 Switch Settings - Nortel BCM200 Installation And Maintenance Manual

Business communications manager
Hide thumbs Also See for BCM200:
Table of Contents

Advertisement

ASM 8 and GASM8 switch settings

In a single-density configuration, such as for DS30 6 or 7 when they are set to the default PDD,
only offset 1 and 2 are available to ASM 8/GASM8. In a double-density configuration, you can
install four GASM8s for each DS30 bus.
number and the dialing numbers (DNs) assigned to each DS30 number.
Table 40 ASM 8 settings
Select
Select
Enter these switch
bus
offset
1
2
2.5 system upgraded to 3.0
on on on on on on 221-228
0
on on off on on on 229-236
1
2
on off on on on on 377-384
2
on off off on on on 385-392
3
on on on on on off 237-244
0
on on off on on off 245-252
1
3
on off on on on off 393-400
2
on off off on on off 401-408
3
on on on on off on 253-260
0
on on off on off on 261-268
1
4
on off on on off on 409-416
2
on off off on off on 417-424
3
on on on on off off 269-276
0
on on off on off off 277-284
1
5
on off on on off off 425-432
2
on off off on off off 433-440
3
on on on off on on 285-292
0
on on off off on on 293-300
1
6
on off on off on on 441-448
2
on off off off on on 449-456
3
on on on off on off 301-308
7***
0
on on off off on off 309-316
1
*****2 on off on off on off 457-464
*****3 on off off off on off 465-472
** The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a
different Start DN, enter the range in the blank column.
*** If your system is configured with a 3/5 split, DS30 7 is not available.
*****Available only on systems set to double density with a 2/6 DS30 split.
GASM8 mode and country switch settings
The GASM8 has a second set of eight DIP switches on the right side, at the rear of the MBM, that
allow you to choose a mode of function, based on country of operation. These settings are
dependant on the version of the system software.
To
settings
assign
these
3
4
5
6
DNs
Chapter 8 Installing a media bay module (MBM)
Table 39
shows the switch settings for each DS30
Select
Enter these switch
offset
settings
1
2
3
3.0 and newer systems
on on on on
0
on on off on
1
on off on on
2
on off off on
3
on on on on
0
on on off on
1
on off on on
2
on off off on
3
on on on on
0
on on off on
1
on off on on
2
on off off on
3
on on on on
0
on on off on
1
on off on on
2
on off off on
3
on on on off
0
on on off off
1
on off on off
2
on off off off
3
on on on off
0
on on off off
1
on off on off
*****2
on off off off
*****3
BCM200/400 4.0 Installation and Maintenance Guide
To
assign
these
4
5
6
DNs
on on
221-228
on on
229-236
on on
237-244
on on
245-252
on off
253-260
on off
261-268
on off
269-276
on off
277-284
off on
285-292
off on
293-300
off on
301-308
off on
309-316
off off
317-324
off off
325-332
off off
333-340
off off
341-348
on on
349-356
on on
357-364
on on
365-372
on on
373-380
on off
381-388
on off
389-396
on off
397-404
on off
405-412
129
**Custom
DN range

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcm400

Table of Contents