◆ Setting 5: Compressor Application

No.
A1-02
Control Method Selection
b1-04
Reverse Operation Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Duty Rating
E1-03
V/f Pattern Selection
L2-01
Momentary Power Loss Operation Selection
L3-04
Stall Prevention Selection during Deceleration
No.
b1-01
Frequency Reference Selection
b1-02
Run Command Selection
b1-04
Reverse Operation Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1

◆ Setting 6: Hoist Application

Note: 1. Read the instructions listed on page
2. Perform Auto-Tuning after selecting the Hoist Application Preset.
No.
A1-02
Control Method Selection
b1-01
Frequency Reference Selection
b6-01
Dwell Reference at Start
b6-02
Dwell Time at Start
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Duty Rating
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
d1-02
Frequency Reference 2
d1-03
Frequency Reference 3
E1-03
V/f Pattern Selection
H2-01
Terminals M1-M2 Function Selection
H2-02
Terminals M3-M4 Function Selection
L2-03
Momentary Power Loss Minimum Baseblock Time
L3-04
Momentary Power Loss Voltage Recovery Ramp Time
L4-01
Speed Agreement Detection Level
L4-02
Speed Agreement Detection Width
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L8-05
Input Phase Loss Protection Selection
L8-07
Output Phase Loss Protection
L8-38
Carrier Frequency Reduction
L8-41
Current Alarm Selection
No.
A1-02
Control Method Selection
b1-01
Frequency Reference Selection
b6-01
Dwell Reference at Start
b6-02
Dwell Time at Start
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
Table 4.13 Compressor: Parameter Settings
Parameter Name
Table 4.14 Compressor: User Parameters (A2-01 to A2-16):
Parameter Name
106
when using Hoist Application Preset
Table 4.15 Hoist: Parameters and Settings
Parameter Name
Table 4.16 Hoist: User Parameters (A2-01 to A2-16):
Parameter Name
Default Setting
0: V/f Control
1: Reverse Prohibited
5.0 s
5.0 s
0: Heavy Duty
0FH
1: Enabled
1: Enabled
No.
E1-03
V/f Pattern Selection
E1-07
Mid Output Frequency
E1-08
Mid Output Frequency Voltage
E2-01
Motor Rated Current
Default Setting
2: Open Loop Vector Control
0: Operator
3.0 Hz
0.3 s
3.0 s
3.0 s
0: Heavy Duty
2: 5 kHz
6.0 Hz
30.0 Hz
50. 0 Hz
0FH
5: Frequency Detection 2
37: During Frequency Output
0.3 s
0: Disabled
2.0 Hz
0.0 Hz
8: UL3 at RUN - Fault
2%
0.5 s
1: Enabled
1: Enabled
1: Enabled below 6 Hz
1: Enabled (alarm is output)
No.
d1-02
Frequency Reference 2
d1-03
Frequency Reference 3
E1-08
Mid Output Frequency Voltage
H2-01
Terminals M1-M2 Function Selection
L1-01
Motor Overload Protection Selection
L4-01
Speed Agreement Detection Level
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
4.6 Application Selection
Parameter Name
Parameter Name
4
105