YASKAWA A1000 Series Technical Manual page 458

High performance vector control drive models: 200 v class: 0.4 to 110 kw 400 v class: 0.4 to 355 kw
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

B.6 Defaults by Drive Model Selection (o2-04) and ND/HD (C6-01)
No.
Model CIMR-A
C6-01
Drive Duty Selection
o2-04
Drive Model Selection
E2-11 (E4-11)
Motor rated Output
b3-04
V/f Gain during Speed Search
b3-06
Output Current 1 during Speed Search
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17 (C5-37)
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01 (E4-01)
Motor Rated Current
E2-02 (E4-02)
Motor Rated Slip
E2-03 (E4-03)
Motor No-Load Current
E2-05 (E4-05)
Motor Line to Line Resistance
E2-06 (E4-06)
Motor Leakage Inductance
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
E5-01
Motor Code Selection
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
n5-02
Motor Acceleration Time
No.
Model CIMR-A
C6-01
Drive Duty Selection
o2-04
Drive Model Selection
E2-11 (E4-11)
Motor rated Output
b3-04
V/f Gain during Speed Search
b3-06
Output Current 1 during Speed Search
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17 (C5-37)
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01 (E4-01)
Motor Rated Current
E2-02 (E4-02)
Motor Rated Slip
E2-03 (E4-03)
Motor No-Load Current
E2-05 (E4-05)
Motor Line to Line Resistance
E2-06 (E4-06)
Motor Leakage Inductance
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
E5-01
Motor Code Selection
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
n5-02
Motor Acceleration Time
458
Name
Unit
Hex.
kW
%
s
2
kgm
A
Hz
A
Ω
%
W
Hex.
s
s
s
s
°C
ms
s
Name
Unit
Hex.
kW
%
s
2
kgm
A
Hz
A
Ω
%
W
Hex.
s
s
s
s
°C
ms
s
2A0069
2A0081
HD
ND
HD
0
1
0
6E
15
18.5
18.5
100
100
100
0.5
0.5
0.5
0.50
0.50
0.50
63.13
57.87
57.87
0.076
0.138
0.138
1
7
1
53
65.8
65.8
1.6
1.67
1.67
15.2
15.7
15.7
0.138
0.101
0.101
17.2
15.7
20.1
272
505
505
120E
120E
120F
2
2
2
1
1
1
0.6
0.6
0.6
0.244
0.317
0.317
120
120
125
2
2
2
2
2
2
10
10
10
0.244
0.317
0.317
2A0169
HD
ND
0
1
73
37
45
80
80
0.5
0.5
0.50
0.50
38.16
35.78
0.273
0.333
1
7
131
160
1.33
1.6
38.2
44
0.039
0.03
18.8
20.2
823
852
1213
1213
2
2
1.1
1.2
0.6
1
0.32
0.387
130
130
0
0
2
2
10
10
0.32
0.387
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
Default Settings
2A0110
ND
HD
ND
1
0
1
6F
70
22
22
30
100
100
80
0.5
0.5
0.5
0.50
0.50
0.50
51.79
51.79
46.27
0.165
0.165
0.220
7
1
7
77.2
77.2
105
1.7
1.7
1.8
18.5
18.5
21.9
0.079
0.079
0.064
19.5
19.5
20.8
538
538
699
120F
1210
1210
2
2
2
1
1
1.1
0.6
0.6
0.6
0.355
0.355
0.323
125
130
130
2
0
0
2
2
2
10
10
10
0.355
0.355
0.323
Default Settings
2A0211
HD
ND
0
1
74
45
55
80
80
0.5
0.5
0.50
2.00
35.78
31.35
0.333
0.490
1
7
160
190
1.6
1.43
44
45.6
0.03
0.022
20.2
20.5
852
960
1214
1214
2
2
1.2
1.3
1
1
0.387
0.317
125
125
0
0
2
2
10
10
0.387
0.317
2A0138
HD
ND
0
1
72
30
37
80
80
0.5
0.5
0.50
0.50
46.27
38.16
0.220
0.273
1
7
105
131
1.8
1.33
21.9
38.2
0.064
0.039
20.8
18.8
699
823
1212
1212
2
2
1.1
1.1
0.6
0.6
0.323
0.32
130
130
0
0
2
2
10
10
0.323
0.32
2A0250
HD
ND
0
1
75
55
75
80
80
0.5
0.7
2.00
2.00
31.35
23.1
0.49
0.90
1
7
190
260
1.43
1.39
45.6
72
0.022
0.023
20.5
20
960
1200
1215
1215
2
2
1.3
1.5
1
1
0.317
0.533
115
115
0
0
2
2
10
10
0.317
0.533

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents