YASKAWA A1000 Series Technical Manual page 429

High performance vector control drive models: 200 v class: 0.4 to 110 kw 400 v class: 0.4 to 355 kw
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

H2-
Function
Setting
1F
Motor Overload Alarm (oL1)
20
Drive Overheat Pre-alarm (oH)
22
Mechanical Weakening Detection
2F
Maintenance Period
30
During Torque Limit
31
During Speed Limit
During Speed Limit in Torque
32
Control
33
Zero Servo Complete
37
During Frequency Output
38
Drive Enabled
39
Watt Hour Pulse Output
3C
LOCAL/REMOTE Status
3D
During Speed Search
3E
PID Feedback Low
3F
PID Feedback High
4A
During KEB Ride-Thru
4B
During Short-Circuit Braking
4C
During Fast Stop
4D
oH Pre-alarm Time Limit
4E
Braking Transistor Fault (rr)
4F
Braking Resistor Overheat (oH)
60
Internal Cooling Fan Alarm
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
H2 Multi-Function Digital Output Settings
All Modes
Closed: oL1 is at 90% of its trip point or greater. An oH3 situation also triggers this alarm.
All Modes
Closed: Heatsink temperature exceeds the parameter L8-02 value.
All Modes
Closed: Mechanical weakening detected.
All Modes
Closed: Cooling fan, electrolytic capacitors, IGBTs, or the soft charge bypass relay may require maintenance.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Closed: When the torque limit has been reached.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Closed: Speed limit has been reached.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Closed: Speed limit has been reached while using Torque Control.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Closed: Zero Servo operation has finished.
All Modes
Open: Either the drive has stopped or baseblock, DC Injection Braking, or Initial Excitation is being performed.
Closed: Drive is running the motor (not in a baseblock state and DC Injection is not being performed).
All Modes
Closed: Multi-function input set for "Drive enable" is closed (H1-
All Modes
Output units are determined by H2-06. Outputs a pulse every 200 ms to indicate the kWh count.
All Modes
Open: REMOTE
Closed: LOCAL
V/f
V/f w/PG
OLV/PM
AOLV/PM
Closed: Speed Search is being executed.
All Modes
Closed: PID feedback level is too low.
All Modes
Closed: The PID feedback level is too high.
All Modes
Closed: KEB Ride-Thru is being performed.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Closed: Short Circuit Braking is active.
All Modes
Closed: A Fast Stop command has been entered from the operator or input terminals.
All Modes
Closed: oH pre-alarm time limit has passed.
All Modes
Closed: The built-in dynamic braking transistor failed.
All Modes
Closed: The dynamic braking resistor has overheated.
All Modes
Closed: Internal cooling fan alarm
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
= 6A)
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
B.3 Parameter Table
Page
common_
TMonly
231
common_
TMonly
231
common_
TMonly
231
common_
TMonly
232
common_
TMonly
232
common_
TMonly
232
common_
TMonly
232
common_
TMonly
232
common_
TMonly
232
common_
TMonly
232
common_
TMonly
232
common_
TMonly
233
common_
TMonly
233
common_
TMonly
233
common_
TMonly
233
common_
TMonly
233
common_
TMonly
233
common_
TMonly
233
common_
TMonly
233
common_
TMonly
233
common_
TMonly
233
common_
TMonly
233
B
429

Hide quick links:

Advertisement

Table of Contents
loading