0: PM Motor Parameter Settings
1: PM Stationary Auto-Tuning
2: PM Stationary Auto-Tuning for Stator Resistance
3: Z-Pulse Offset Tuning
8: Inertia Tuning
9: ASR Gain Auto-Tuning
T2-02: PM Motor Code Selection
If the drive is operating a Yaskawa PM motor from the SMRA, SSR1, or SST4 series, enter the motor code for the motor
in parameter T2-02. This will automatically set parameters T2-03 through T2-14. If using a specialized motor or one
designed by a manufacturer other than Yaskawa, set T2-02 to FFFF. Data from the motor nameplate or the motor test
report will then need to be entered as prompted.
Only the designated PM motor codes may be entered. The PM motor codes accepted by the drive will differ by the
control mode that has been selected. Refer to
No.
T2-02
T2-03: PM Motor Type
Selects the type of PM motor the drive will operate.
No.
T2-03
0: IPM motor
1: SPM motor
T2-04: PM Motor Rated Power
Specifies the motor rated power in kilowatts.
No.
T2-04
T2-05: PM Motor Rated Voltage
Sets the motor rated voltage.
No.
T2-05
<1>
<1> The setting range and default value shown here is for a 200 V class drive. These values double when using a 400 V class unit.
T2-06: PM Motor Rated Current
Enter the motor rated current in amps.
No.
T2-06
T2-07: PM Motor Base Frequency
Enter the motor base frequency in Hz.
Note: T2-07 will be displayed when in OLV/PM.
No.
T2-07
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
E5: PM Motor Settings on page 204
Name
PM Motor Code Selection
Name
PM Motor Type
Name
PM Motor Rated Power
Name
PM Motor Rated Voltage
Name
PM Motor Rated Current
Name
PM Motor Base Frequency
4.7 Auto-Tuning
for motor codes.
Setting Range
0000 to FFFF
Depending on A1-02 and o2-04
Setting Range
0, 1
Setting Range
0.00 to 650.00 kW
Setting Range
0.0 to 255.0 V
Setting Range
10% to 200% of the drive rated
current.
Setting Range
0.0 to 400.0 Hz
Default
Default
1
Default
Depending on o2-04
Default
200.0 V
4
Default
Depending on o2-04
Default
87.5 Hz
117