YASKAWA A1000 Series Technical Manual page 459

High performance vector control drive models: 200 v class: 0.4 to 110 kw 400 v class: 0.4 to 355 kw
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

No.
Model CIMR-A
C6-01
Drive Duty Selection
o2-04
Drive Model Selection
E2-11 (E4-11)
Motor rated Output
b3-04
V/f Gain during Speed Search
b3-06
Output Current 1 during Speed Search
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17 (C5-37)
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01 (E4-01)
Motor Rated Current
E2-02 (E4-02)
Motor Rated Slip
E2-03 (E4-03)
Motor No-Load Current
E2-05 (E4-05)
Motor Line to Line Resistance
E2-06 (E4-06)
Motor Leakage Inductance
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
E5-01
Motor Code Selection
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
n5-02
Motor Acceleration Time
Table B.9 400 V Class Drives Default Settings by Drive Capacity and ND/HD Setting
No.
Model CIMR-A
C6-01
Drive Duty Selection
o2-04
Drive Model Selection
E2-11 (E4-11)
Motor rated Output
b3-04
V/f Gain during Speed Search
b3-06
Output Current 1 during Speed Search
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17 (C5-37)
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01 (E4-01)
Motor Rated Current
E2-02 (E4-02)
Motor Rated Slip
E2-03 (E4-03)
Motor No-Load Current
E2-05 (E4-05)
Motor Line to Line Resistance
E2-06 (E4-06)
Motor Leakage Inductance
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
E5-01
Motor Code Selection
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
n5-02
Motor Acceleration Time
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
B.6 Defaults by Drive Model Selection (o2-04) and ND/HD (C6-01)
Name
Unit
Hex.
kW
%
s
2
kgm
A
Hz
A
Ω
%
W
Hex.
s
s
s
s
°C
ms
s
Name
Unit
Hex.
kW
%
s
2
kgm
A
Hz
A
Ω
%
W
Hex.
s
s
s
s
°C
ms
s
Default Settings
2A0312
HD
ND
HD
0
1
76
75
90
90
80
80
80
0.7
0.7
0.7
2.00
2.00
2.00
23.1
20.65
20.65
0.90
1.10
1.10
1
7
260
260
260
1.39
1.39
1.39
72
72
72
0.023
0.023
0.023
20
20
20
1200
1200
1200
1216
1216
FFFF
2
2
1.5
1.5
1.5
1
1
0.533
0.592
0.592
120
120
120
0
0
2
2
10
10
100
0.533
0.592
0.592
Default Settings
4A0002
4A0004
HD
ND
HD
0
1
0
92
93
0.4
0.75
0.75
100
100
100
0.5
0.5
0.5
0.50
0.50
0.50
576.4
447.4
447.4
0.0015
0.0028
0.0028
0.0068
1
7
1
1
1.6
1.6
2.9
2.6
2.6
0.6
0.8
0.8
38.198
22.459
22.459
18.2
14.3
14.3
14
26
26
1232
1232
1233
0.1
0.1
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.178
0.142
0.142
110
110
110
2
2
2
2
2
2
10
10
10
0.178
0.142
0.142
2A0360
ND
HD
0
1
0
77
110
110
80
80
0.7
0.7
2.00
2.00
18.12
18.12
1.90
1.90
1
7
1
260
260
1.39
1.39
72
72
0.023
0.023
20
20
1200
1200
FFFF
FFFF
2
2
2
1.7
1.7
1
1
1
0.646
0.646
120
120
0
0
0
2
2
2
100
100
0.646
0.646
4A0005
ND
HD
ND
1
0
1
94
1.5
1.5
2.2
100
100
100
0.5
0.5
0.5
0.50
0.50
0.50
0.50
338.8
338.8
313.6
313.6
0.0068
0.0088
0.0088
7
1
7
3.1
3.1
4.2
2.5
2.5
3
1.4
1.4
1.5
10.1
10.1
6.495
6.495
18.3
18.3
18.7
18.7
53
53
77
1233
1235
1235
1236
0.2
0.3
0.3
0.4
0.4
0.5
0.3
0.3
0.3
0.166
0.166
0.145
0.145
110
110
110
2
2
2
2
2
2
10
10
10
0.166
0.166
0.145
0.145
2A0415
ND
1
78
110
80
0.7
2.00
18.12
1.90
7
260
1.39
72
0.023
20
1200
FFFF
2
1.7
1
0.646
120
0
2
100
0.646
4A0007
HD
ND
0
1
95
2.2
3.0
100
100
0.5
0.5
0.50
265.7
0.0158
1
7
4.2
5.7
3
2.7
1.5
1.9
4.360
19
77
105
1236
0.5
0.5
0.5
0.5
0.3
0.3
0.145
110
110
2
2
2
2
10
10
0.145
B
459

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents