7.5 Drive Replacement

◆ Replacing the Drive

WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious
personal injury. Before servicing the drive, disconnect all power to the equipment. The internal capacitor remains charged even after
the power supply is turned off. After shutting off the power, wait for at least the amount of time specified on the drive before touching
any components.
WARNING! Electrical Shock Hazard. Do not allow unqualified personnel to perform work on the drive. Failure to comply could result in
serious injury. Installation, maintenance, inspection and servicing must be performed only by authorized personnel familiar with
installation, adjustment and maintenance of AC drives.
NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling the drive and circuit
boards. Failure to comply may result in ESD damage to the drive circuitry.
The following procedure explains how to replace a drive. This section provides instructions for drive replacement only.
To install option boards or other types of options, then refer to the specific manuals for those options.
NOTICE: When transferring a braking transistor, braking resistor, or other type of option from a damaged drive to a new replacement
drive, make sure they are working properly before reconnecting them to the new drive. Replace broken options to prevent immediate
break down of the replacement drive.
1.
Remove the terminal cover.
Figure 7.42
2.
Loosen the screws holding the terminal board in place. Take out the screw securing the bottom cover and
remove the bottom cover from the drive.
Note: Drives set up for compliance with IP00 do not have a bottom cover.
Figure 7.43
3.
Slide the terminal board as illustrated by the arrows, and remove it from the drive along with the bottom cover.
Figure 7.44
370
YEG
Figure 7.42 Drive Replacement: Removing the Terminal Cover
YEG
Figure 7.43 Drive Replacement: Removing the Terminal Board
YEG
Figure 7.44 Drive Replacement: Remove the Terminal Board
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual