H Parameters: Multi-Function Terminals - YASKAWA A1000 Series Technical Manual

High performance vector control drive models: 200 v class: 0.4 to 110 kw 400 v class: 0.4 to 355 kw
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

No.(Addr.)
Name
F6-53
DeviceNet PPA Setting
(3C4H)
F6-54
DeviceNet Idle Mode Fault
(3C5H)
Detection
F6-55
DeviceNet Baud Rate Monitor
(3C6H)
F6-56
DeviceNet Speed Scaling
(3D7H)
F6-57
DeviceNet Current Scaling
(3D8H)
F6-58
DeviceNet Torque Scaling
(3D9H)
F6-59
DeviceNet Power Scaling
(3DAH)
F6-60
DeviceNet Voltage Scaling
(3DBH)
F6-61
DeviceNet Time Scaling
(3DCH)
F6-62
DeviceNet Heartbeat Interval
(3DDH)
F6-63
DeviceNet Network MAC ID
(3DEH)
F6-64 to
F6-71
Reserved
(3DFH to
3C8H)
<3> Parameter setting value is not reset to the default value when the drive is initialized.

◆ H Parameters: Multi-Function Terminals

H parameters assign functions to the multi-function input and output terminals.
H1: Multi-Function Digital Inputs
No.(Addr.)
Name
H1-01
Multi-Function Digital Input
(438H)
Terminal S1 Function Selection
H1-02
Multi-Function Digital Input
(439H)
Terminal S2 Function Selection
H1-03
Multi-Function Digital Input
(400H)
Terminal S3 Function Selection
H1-04
Multi-Function Digital Input
(401H)
Terminal S4 Function Selection
H1-05
Multi-Function Digital Input
(402H)
Terminal S5 Function Selection
H1-06
Multi-Function Digital Input
(403H)
Terminal S6 Function Selection
H1-07
Multi-Function Digital Input
(404H)
Terminal S7 Function Selection
H1-08
Multi-Function Digital Input
(405H)
Terminal S8 Function Selection
<31> Value in parenthesis is the default setting when a 3-wire initialization is performed (A1-03 = 3330).
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
All Modes
Sets the format of the data set from the drive to the DeviceNet master.
All Modes
0: Enabled
1: Disabled, no fault detection
All Modes
Used to verify the baud rate running on the network.
0: 125 kbps
1: 250 kbps
2: 500 kbps
All Modes
Sets the scaling factor for the speed monitor in DeviceNet.
All Modes
Sets the scaling factor for the output current monitor in DeviceNet.
All Modes
Sets the scaling factor for the torque monitor in DeviceNet.
All Modes
Sets the scaling factor for the power monitor in DeviceNet.
All Modes
Sets the scaling factor for the voltage monitor in DeviceNet.
All Modes
Sets the scaling factor for the time monitor in DeviceNet.
All Modes
Sets the heartbeat interval for DeviceNet communications.
All Modes
Used to verify the MAC ID the drive has been assigned.
All Modes
Reserved for Dynamic I/O Assembly Parameters.
All Modes
Assigns a function to the multi-function digital inputs.
Refer to
H1 Multi-Function Digital Input Selections on page 424
values.
Note: Unused terminals should be set to F.
Description
Description
for a description of setting
B.3 Parameter Table
Setting
Page
Default: 71
common_
TMonly
Min: 0
Max: 255
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
TMonly
Default: 0
Min: 0
Max: 2
Default: 0
common_
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: -15
Max: 15
Default: 0
common_
TMonly
Min: 0
Max: 10
Default: 0
common_
TMonly
Min: 0
Max: 63
common_
TMonly
Setting
Page
Default: 40 (F)
<31>
Min: 1
214
Max: 9F
Default: 41 (F)
<31>
Min: 1
214
Max: 9F
Default: 24
Min: 0
214
Max: 9F
Default: 14
Min: 0
214
Max: 9F
Default: 3(0)
<31>
Min: 0
214
Max: 9F
Default: 4(3)
<31>
Min: 0
214
Max: 9F
Default: 6(4)
<31>
Min: 0
214
Max: 9F
Default: 8
Min: 0
214
Max: 9F
B
423