YASKAWA A1000 Series Technical Manual page 417

High performance vector control drive models: 200 v class: 0.4 to 110 kw 400 v class: 0.4 to 355 kw
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

No.(Addr.)
Name
E4-06
Motor 2 Leakage Inductance
(326H)
E4-07
Motor 2 Motor Iron-Core
(343H)
Saturation Coefficient 1
E4-08
Motor 2 Motor Iron-Core
(344H)
Saturation Coefficient 2
E4-09
Motor 2 Mechanical Loss
(33FH)
E4-10
Motor 2 Iron Loss
(340H)
E4-11
Motor 2 Rated Power
(327H)
<9> Default setting value is dependent on the drive model (o2-04) and the Drive Duty (C6-01).
<19> This value's number of decimal places depends on the drive model and the Heavy/Normal duty selection in parameter C6-01. The value will
have two decimal places (0.01 A) if the drive is set for a Maximum Applicable Motor Capacity up to 11 kW (refer to
and one decimal place (0.1 A) if the set Maximum Applicable Motor Capacity is higher than 11 kW.
E5: PM Motor Settings
No.(Addr.)
Name
E5-01
(329H)
Motor Code Selection
<3>
E5-02
(32AH)
Motor Rated Power
<3>
E5-03
(32BH)
Motor Rated Current
<3>
E5-04
(32CH)
Number of Motor Poles
<3>
E5-05
(32DH)
Motor Stator Resistance
<3>
E5-06
(32EH)
Motor d-Axis Inductance
<3>
E5-07
(32FH)
Motor q-Axis Inductance
<3>
E5-09
Motor Induction Voltage Constant
(331H)
1
<3>
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the voltage drop for motor 2 due to motor leakage inductance as a percentage of rated
voltage. Automatically set during Auto-Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Set to the motor iron saturation coefficient at 50% of magnetic flux for motor 2. Automatically
set during Auto-Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Set to the motor iron saturation coefficient at 75% of magnetic flux for motor 2. This value is
automatically set during Auto-Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor mechanical loss for motor 2 as a percentage of motor rated power (kW).
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor iron loss.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated capacity in kW. Automatically set during Auto-Tuning.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Enter the Yaskawa motor code for the PM motor being used. Various motor parameters are
automatically set based on the value of this parameter. Setting that were changed manually will
be overwritten by the defaults of the selected motor code.
Note: Set to FFFF when using a non-Yaskawa PM motor.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the rated capacity of the motor.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated current.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the number of motor poles.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Set the resistance for each motor phase.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the d-axis inductance for the PM motor.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the q-axis inductance for the PM motor.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Set the induced phase peak voltage in units of 0.1 mV (rad/s) [electrical angle]. Set this
parameter when using a Yaskawa SSR1 Series PM motor with derated torque, or a Yaskawa
SST4 Series motor with constant torque.
When setting this parameter, E5-24 should be set to 0.
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
common_
Default:
<9>
TMonly
Min: 0.0%
203
Max: 40.0%
common_
Default: 0.50
TMonly
Min: 0.00
203
Max: 0.50
common_
Default: 0.75
TMonly
Min: E4-07
203
Max: 0.75
Default: 0.0%
common_
TMonly
Min: 0.0%
203
Max: 10.0%
Default:
<9>
common_
TMonly
Min: 0 W
203
Max: 65535 W
Default:
<9>
common_
TMonly
Min: 0.00 kW
204
Max: 650.00 kW
Table A.2
and
Table
Setting
Page
common_
TMonly
Default:
<4> <23>
Min: 0000
204
Max: FFFF
<28>
Default:
<14>
common_
TMonly
Min: 0.10 kW
204
Max: 650.00 kW
Default:
<14>
Min: 10% of drive rated
common_
TMonly
current
204
Max: 200% of drive
rated current
<19>
Default:
<14>
common_
TMonly
Min: 2
204
Max: 48
Default:
<14>
common_
TMonly
Min: 0.000 Ω
205
Max: 65.000 Ω
Default:
<14>
common_
TMonly
Min: 0.00 mH
205
Max: 300.00 mH
Default:
<14>
common_
TMonly
Min: 0.00 mH
205
Max: 600.00 mH
common_
TMonly
Default:
<14>
Min: 0.0 mV/(rad/s)
205
Max:
2000.0 mV/(rad/s)
A.3)