8.2

Drive Options and Peripheral Devices

The following table of peripheral devices lists the names of the various accessories and options available for Yaskawa
drives. Contact Yaskawa or your Yaskawa agent to order these peripheral devices.
• Peripheral Device Selection: Refer to the Yaskawa catalog for selection and part numbers.
• Peripheral Device Installation: Refer to the corresponding option manual for installation instructions.
Option
DC Reactor
AC Reactor
Braking Resistor
Braking Unit
Analog Input
Analog Monitor
Digital Input
Digital Output
Complementary PG
Line Driver PG
PROFIBUS-DP
CC-Link
DeviceNet
CANopen
MECHATROLINK-II
LED Operator
Remote Operator Cable
USB Copy Unit
Attachment for External Heatsink
NEMA 1 Kit
Installation Support Set A
Installation Support Set B
24 V Power Supply
DriveWizard Plus
DriveWorksEZ
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
Model Number
-
-
ERF-150WJ Series
CDBR Series
Input / Output Option Cards
AI-A3
AO-A3
DI-A3
DO-A3
Motor Speed Feedback Option Cards
PG-B3
PG-X3
Communication Options Cards
SI-P3
SI-C3
SI-N3
SI-S3
SI-T3
JVOP-182
WV001/WV003
JVOP-181
EZZ020786
EZZ020787
EZZ020642A
EZZ020642B
PS-A10L, PS-A10H
Contact Yaskawa
Contact Yaskawa
8.2 Drive Options and Peripheral Devices
Power Options
Improves the power factor by suppressing harmonic distortion from the power
supply.
Protects the drive when operating from a large power supply and improves the
power factor by suppressing harmonic distortion. Highly recommended for power
supplies that exceed 600 kVA.
For use with systems that require dynamic braking with up to 3% ED. If higher
ED is required, use a Braking Resistor Unit.
External braking transistor
Allows high precision, high resolution analog reference input.
Input channels: 3
Voltage input: -10 to 10 Vdc (20 kΩ), 13 bit signed
Current input: 4 to 20 mA or 0 to 20 mA (250 kΩ), 12 bit
Provides extra multi-function analog output terminals.
Output channels: 2
Output voltage: -10 to 10 V, 11 bit (signed)
Used to set the frequency reference by digital inputs
Input channels: 18 (including SET signal and SIGN signal)
Input signal type: BCD 16 bit (4 digit), 12 bit (3 digit), 8 bit (2 digit)
Input signal: 24 Vdc, 8 mA
Provides extra insulated multi-function digital outputs.
Photocoupler relays: 6 (48 V, up to 50 mA)
Contact relays: 2 (250 Vac/up to 1 A, 30 Vdc/up to 1 A)
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), for HTL encoder connection,
50 kHz max
Output: 3 track, open collector
Encoder power supply: 12 V, max current 200 mA
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), line driver, 300 kHz max
Output: 3 track, line driver
Encoder power supply: 5 V or 12 V, max current 200 mA
Connects to a PROFIBUS-DP network.
Connects to a CC-Link network
Connects to a DeviceNet network
Connects to a CANopen network
Connects to a MECHATROLINK-II network
Interface Options
5-digits LED operator; max. cable length for remote usage: 3 m
Extension cable (1 m or 3 m) to connect the digital operator for remote operation
RJ-45, 8 pin straight through, UTP CAT5e cable
Allows the user to copy and verify parameter settings between drives. Can also be
used as an adapter to connect the drive to the USB port on a PC.
Mechanical Options
Installation kit for mounting the drive with the heatsink outside of the panel (Side-
by-Side mounting possible)
Parts to make the drive conform to NEMA Type 1 enclosure requirements
For installing the digital operator keypad on the outside of an enclosure panel that
houses the drive. Also refer to
Others
Option to supply the drive controller with 24 Vdc power during main power loss
PC Software Tools
PC tool for drive setup and parameter management
PC tool for enhanced programming of the drive
Description
Digital Operator Remote Installation on page
43.