YASKAWA A1000 Series Technical Manual page 436

High performance vector control drive models: 200 v class: 0.4 to 110 kw 400 v class: 0.4 to 355 kw
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

B.3 Parameter Table
No. (Addr.)
Name
L3-21
Accel/Decel Rate Calculation Gain
(466H)
L3-22
Deceleration Time at Stall
(4F9H)
Prevention during Acceleration
L3-23
Automatic Reduction Selection for
(4FDH)
Stall Prevention during Run
L3-24
Motor Acceleration Time for
(46EH)
Inertia Calculations
L3-25
Load Inertia Ratio
(46FH)
L3-26
Additional DC Bus Capacitors
(455H)
L3-27
Stall Prevention Detection Time
(456H)
<8> Parameter value is changed if E2-11 is manually changed or changed by Auto-Tuning.
<9> Default setting is determined by the drive model (o2-04) and duty selection (C6-01).
<10> Default setting is determined by the control mode (A1-02).
<14> Default setting value is dependent on the motor code set to parameter E5-01.
<18> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<33> Default setting value is dependent on the setting for the input voltage (E1-01).
<34> Setting range is dependent on the control mode (A1-02). When using CLV, OLV/PM, or AOLV/PM, the setting range is 0 to 2 s.
<35> The upper limit of the setting range is determined by the values set to the duty selection (C6-01) and the carrier frequency reduction selection
(L8-38).
L4: Speed Detection
No. (Addr.)
Name
L4-01
Speed Agreement Detection Level
(499H)
L4-02
Speed Agreement Detection Width
(49AH)
L4-03
Speed Agreement Detection Level
(49BH)
(+/-)
L4-04
Speed Agreement Detection Width
(49CH)
(+/-)
L4-05
Frequency Reference Loss
(49DH)
Detection Selection
L4-06
Frequency Reference at Reference
(4C2H)
Loss
L4-07
Speed Agreement Detection
(470H)
Selection
<10> Default setting is determined by the control mode (A1-02).
436
All Modes
Sets the proportional gain used to calculate the deceleration rate during KEB Ride-Thru, ov
suppression function, and Stall Prevention during deceleration (L3-04 = 2).
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the deceleration time used for Stall Prevention during acceleration in OLV/PM.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Sets the Stall Prevention level set in L3-06 that is used throughout the entire frequency range.
1: Automatic Stall Prevention level reduction in the constant output range. The lower limit
value is 40% of L3-06.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time needed to accelerate the uncoupled motor at rated torque from stop to the
maximum frequency.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the ratio between the motor and machine inertia.
All Modes
When DC bus capacitors have been added externally, be sure to add those values to the internal
capacitor table for proper DC bus calculations.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time the current must exceed the Stall Prevention level to activate Stall Prevention.
All Modes
L4-01 sets the frequency detection level for digital output functions H2-
L4-02 sets the hysteresis or allowable margin for speed detection.
All Modes
L4-03 sets the frequency detection level for digital output functions H2-
L4-04 sets the hysteresis or allowable margin for speed detection.
All Modes
0: Stop. Drive stops when the frequency reference is lost.
1: Run. Drive runs at a reduced speed when the frequency reference is lost.
All Modes
Sets the percentage of the frequency reference that the drive should run with when the
frequency reference is lost.
All Modes
0: No detection during baseblock.
1: Detection always enabled.
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Description
= 2, 3, 4, 5.
= 13, 14, 15, 16.
Setting
common_
Default: 1.00
TMonly
Min: 0.10
Max: 10.00
Default: 0.0 s
common_
TMonly
Min: 0.0 s
Max: 6000 s
common_
TMonly
Default: 0
Min: 0
Max: 1
common_
Default:
<8> <9> <14>
TMonly
Min: 0.001 s
Max: 10.000 s
Default: 1.0
common_
TMonly
Min: 1.0
Max: 1000.0
common_
Default: 0 μF
TMonly
Min: 0 μF
Max: 65000 μF
Default: 50 ms
common_
TMonly
Min: 0 ms
Max: 5000 ms
Setting
Default: 0.0 Hz
Min: 0.0 Hz
common_
Max: 400.0 Hz
TMonly
Default:
<10>
Min: 0.0 Hz
Max: 20.0 Hz
Default: 0.0 Hz
Min: -400.0 Hz
common_
Max: 400.0 Hz
TMonly
Default:
<10>
Min: 0.0 Hz
Max: 20.0 Hz
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
Default: 80%
TMonly
Min: 0.0%
Max: 100.0%
common_
Default: 0
TMonly
Min: 0
Max: 1
Page
261
257
259
261
261
262
262
Page
262
262
262
262
262
263
263