YASKAWA A1000 Series Technical Manual page 419

High performance vector control drive models: 200 v class: 0.4 to 110 kw 400 v class: 0.4 to 355 kw
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

No.(Addr.)
Name
F1-08
Overspeed Detection Level
(387H)
F1-09
Overspeed Detection Delay Time
(388H)
F1-10
Excessive Speed Deviation
(389H)
Detection Level
F1-11
Excessive Speed Deviation
(38AH)
Detection Delay Time
F1-12
PG 1 Gear Teeth 1
(38BH)
F1-13
PG 1 Gear Teeth 2
(38CH)
F1-14
PG Open-Circuit Detection Time
(38DH)
F1-18
dv3 Detection Selection
(3ADH)
F1-19
dv4 Detection Selection
(3AEH)
F1-20
PG Option Card Disconnect
(3B4H)
Detection 1
F1-21
PG 1 Signal Selection
(3BCH)
F1-30
PG Card Option Port for Motor 2
(3AAH)
Selection
F1-31
PG 2 Pulses Per Revolution
(3B0H)
F1-32
PG 2 Rotation Selection
(3B1H)
F1-33
PG 2 Gear Teeth 1
(3B2H)
F1-34
PG 2 Gear Teeth 2
(3B3H)
F1-35
PG 2 Division Rate for Pulse
(3BEH)
Monitor
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the overspeed detection level as a percentage of the maximum output frequency.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time in seconds for an overspeed situation to trigger a fault (oS).
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the speed deviation detection level as a percentage of the maximum output frequency.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time in seconds for a speed deviation situation to trigger a fault (dEv).
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the gear ratio between the motor shaft and the encoder (PG).
A gear ratio of 1 will be used if either of these parameters is set to 0.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the time required to trigger a PG Open fault (PGo).
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Disabled
1: Enabled
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Disabled
n: Number of pulses that the A and B pulse are reversed that triggers dv4 detection.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Disabled
1: Enabled
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: A pulse detection
1: AB pulse detection
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the port for the PG option card used by motor 2.
0: CN5-C
1: CN5-B
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the number of pulses for a PG option card connected to port CN5-B.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Pulse A leads
1: Pulse B leads
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the gear ratio between the motor shaft and the encoder (PG).
A gear ratio of 1 will be used if either of these parameters is set to 0.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the division ratio for the pulse monitor used of the PG option card 2 installed to connector
CN5-B. By setting "xyz", the division ratio becomes = [(1 + x) / yz].
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
Default: 115%
common_
TMonly
Min: 0%
206
Max: 120%
Default:
<10>
common_
TMonly
Min: 0.0 s
206
Max: 2.0 s
Default: 10%
common_
TMonly
Min: 0%
207
Max: 50%
Default: 0.5 s
common_
TMonly
Min: 0.0 s
207
Max: 10.0 s
Default: 0
Min: 0
207
common_
Max: 1000
TMonly
Default: 0
Min: 0
207
Max: 1000
Default: 2.0 s
common_
TMonly
Min: 0.0 s
206
Max: 10.0 s
common_
Default: 10
TMonly
Min: 0
208
Max: 10
common_
Default: 128
TMonly
Min: 0
208
Max: 5000
common_
Default: 1
TMonly
Min: 0
208
Max: 1
common_
Default: 0
TMonly
Min: 0
208
Max: 1
common_
Default: 1
TMonly
Min: 0
208
Max: 1
Default: 1024 ppr
common_
TMonly
Min: 0 ppr
206
Max: 60000 ppr
common_
Default: 0
TMonly
Min: 0
207
Max: 1
Default: 0
Min: 0
207
common_
Max: 1000
TMonly
Default: 0
Min: 0
207
Max: 1000
common_
Default: 1
TMonly
Min: 1
207
Max: 132
B