YASKAWA A1000 Series Technical Manual page 448

High performance vector control drive models: 200 v class: 0.4 to 110 kw 400 v class: 0.4 to 355 kw
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

B.3 Parameter Table
No. (Addr.)
Name
U1-11
Output Terminal Status
(4AH)
U1-12
Drive Status
(4BH)
U1-13
Terminal A1 Input Level
(4EH)
U1-14
Terminal A2 Input Level
(4FH)
U1-15
Terminal A3 Input Level
(50H)
U1-16
Output Frequency after Soft
(53H)
Starter
U1-17
DI-A3 Input Status
(58H)
U1-18
oPE Fault Parameter
(61H)
U1-19
MEMOBUS/Modbus Error
(66H)
Code
U1-21
AI-A3 Terminal V1 Input
(77H)
Voltage Monitor
U1-22
AI-A3 Terminal V2 Input
(72AH)
Voltage Monitor
U1-23
AI-A3 Terminal V3 Input
(72BH)
Voltage Monitor
448
All Modes
Displays the output terminal status.
U1 - 11=
0 0 0 0 0 0 0 0
YEG
All Modes
Verifies the drive operation status.
U1 - 12=
0 0 0 0 0 0 0 0
YEG
All Modes
Displays the signal level to analog input terminal A1.
All Modes
Displays the signal level to analog input terminal A2.
All Modes
Displays the signal level to analog input terminal A3.
All Modes
Displays output frequency with ramp time and S-curves. Units determined by o1-03.
All Modes
Displays the reference value input from the DI-A3 option card.
Display will appear in hexadecimal as determined by the digital card input selection in F3-01.
3FFFF: Set (1 bit) + sign (1 bit) + 16 bit
All Modes
Displays the parameter number that caused the oPE
All Modes
Displays the contents of a MEMOBUS/Modbus error.
U1 - 19=
0 0 0 0 0 0 0 0
YEG
All Modes
Displays the input voltage to terminal V1 on analog input card AI-A3.
All Modes
Displays the input voltage to terminal V2 on analog input card AI-A3.
All Modes
Displays the input voltage to terminal V3 on analog input card AI-A3.
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
Description
1
Multi-Function
Digital Output
(terminal M1-M2)
1
Multi-Function
Digital Output
(terminal M3-M4)
1
Multi-Function
Digital Output
(terminal M5-M6)
Not Used
1
Fault Relay
(terminal MA-MC closed
MA-MC open)
1
During run
1
During zero-speed
1
During REV
1
During fault reset
signal input
1
During speed agree
1
Drive ready
1
During alarm
detection
1
During fault detection
or Err (EEPROM write error) error.
1
CRC Error
1
Data Length Error
0
Not Used
1
Parity Error
1
Overrun Error
1
Framing Error
1
Timed Out
0
Not Used
Analog Output
Unit
Level
common_
TMonly
No signal output
available
common_
TMonly
No signal output
available
common_
TMonly
10 V: 100%
0.1%
common_
TMonly
10 V: 100%
0.1%
common_
TMonly
10 V: 100%
0.1%
common_
TMonly
10 V: Max frequency
0.01 Hz
common_
TMonly
No signal output
available
common_
No signal output
TMonly
available
common_
TMonly
No signal output
available
common_
TMonly
10 V: 100%
0.1%
common_
TMonly
10 V: 100%
0.1%
common_
TMonly
10 V: 100%
0.1%
Page

Hide quick links: