B.3 Parameter Table
H2-
Function
Setting
61
Rotor Position Detection Complete
90 to 92
DriveWorksEZ Digital Outputs 1 to 3
100 to 192
Function 0 to 92 with Inverse Output
H3: Multi-Function Analog Inputs
No.(Addr.)
Name
H3-01
Terminal A1 Signal Level
(410H)
Selection
H3-02
Terminal A1 Function Selection
(434H)
H3-03
(411H)
Terminal A1 Gain Setting
H3-04
(412H)
Terminal A1 Bias Setting
H3-05
Terminal A3 Signal Level
(413H)
Selection
H3-06
Terminal A3 Function Selection
(414H)
H3-07
(415H)
Terminal A3 Gain Setting
H3-08
(416H)
Terminal A3 Bias Setting
H3-09
Terminal A2 Signal Level
(417H)
Selection
H3-10
Terminal A2 Function Selection
(418H)
H3-11
(419H)
Terminal A2 Gain Setting
H3-12
(41AH)
Terminal A2 Bias Setting
H3-13
Analog Input Filter Time Constant
(41BH)
H3-14
Analog Input Terminal Enable
(41CH)
Selection
430
H2 Multi-Function Digital Output Settings
V/f
V/f w/PG
OLV/PM
AOLV/PM
Closed: Drive has successfully detected the rotor position of the PM motor.
All Modes
Reserved for DWEZ digital output functions.
All Modes
Inverts the output switching of the multi-function output functions.
Set the last two digits of 1
to reverse the output signal of that specific function.
All Modes
0: 0 to 10 V
1: –10 to 10 V
All Modes
Sets the function of terminal A1.
All Modes
Sets the level of the input value selected in H3-02 when 10 V is input at terminal A1.
All Modes
Sets the level of the input value selected in H3-02 when 0 V is input at terminal A1.
All Modes
0: 0 to 10 V
1: –10 to 10 V
All Modes
Sets the function of terminal A3.
All Modes
Sets the level of the input value selected in H3-06 when 10 V is input at terminal A3.
All Modes
Sets the level of the input value selected in H3-06 when 0 V is input at terminal A3.
All Modes
0: 0 to 10 V
1: –10 to 10 V
2: 4 to 20 mA
3: 0 to 20 mA
Note: Use DIP switch S1 to set input terminal A2 for a current or a voltage input signal.
All Modes
Sets the function of terminal A2.
All Modes
Sets the level of the input value selected in H3-10 when 10 V (20 mA) is input at terminal A2.
All Modes
Sets the level of the input value selected in H3-10 when 0 V (0 or 4 mA) is input at terminal A2.
All Modes
Sets a primary delay filter time constant for terminals A1, A2, and A3. Used for noise filtering.
All Modes
Determines which of the analog input terminals will be enabled when a digital input
programmed for "Analog input enable" (H1-
1: Terminal A1 only
2: Terminal A2 only
3: Terminals A1 and A2 only
4: Terminal A3 only
5: Terminals A1 and A3
6: Terminals A2 and A3
7: All terminals enabled
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
Description
OLV
CLV
CLV/PM
Description
= C) is activated.
common_
TMonly
common_
TMonly
common_
TMonly
Setting
common_
Default: 0
TMonly
Min: 0
Max: 1
Default: 0
common_
TMonly
Min: 0
Max: 31
Default: 100.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
common_
Default: 0
TMonly
Min: 0
Max: 1
Default: 2
common_
TMonly
Min: 0
Max: 31
Default: 100.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
common_
TMonly
Default: 2
Min: 0
Max: 3
Default: 0
common_
TMonly
Min: 0
Max: 31
Default: 100.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
Default: 0.03 s
common_
TMonly
Min: 0.00 s
Max: 2.00 s
common_
TMonly
Default: 7
Min: 1
Max: 7
Page
233
233
233
Page
234
234
234
234
235
235
236
236
236
236
236
236
236
237