5.9 n: Special Adjustments
Calculation
The motor acceleration time can be calculated by,
π J
n
Motor
rated
n5-02 =
30 T
rated
or
4 π J
f
Motor
rated
n5-02 =
p T
rated
Measuring Acceleration Time
Take the following steps when measuring the motor acceleration time.
1.
Decouple motor and load.
2.
Make sure Auto-Tuning has been performed or that the correct motor data has been entered manually.
3.
Make sure that the speed loop (ASR) has been set up properly.
4.
Set the acceleration time to zero.
5.
Set the forward torque limit in parameter L7-01 to 100%.
6.
Set the frequency reference equal to the motor rated speed.
7.
While monitoring the motor speed in U1-05, start the motor in the forward direction and measure the time it takes
to reach the rated speed.
8.
Reverse the parameter settings above and set the measured time to parameter n5-02.
n5-03: Feed Forward Control Gain
Parameter n5-03 sets the inertia ratio of the load connected to the motor.
No.
n5-03
This value can be set automatically by Inertia Auto-Tuning. If Inertia Auto Tuning cannot be performed, determine the
value for parameter n5-03 using the following steps.
1.
Setup parameter n5-02 correctly.
2.
Couple motor and load.
3.
Set the acceleration time C1-01 to 0.
4.
Set the torque limits in the L7-
5.
Set the frequency reference equal to a value in the upper speed range of the machine (f
6.
While monitoring the motor speed in U1-05, start the motor in the forward direction and measure the time it takes
to reach the rated speed (t
7.
Reverse the parameter settings above and calculate the set value for parameter n5-03 using the formula below.
t
T
f
accel
Lim_Test
rated
n5-03 =
n5-02
f
100
ref_Test

◆ n6: Online Tuning

Online Tuning prevents loss from insufficient torque and diminished speed control accuracy due to fluctuating motor
temperature.
n6-01: Online Tuning Selection
Selects the type of motor data Online Tuning uses for Open Loop Vector Control.
No.
n6-01
280
Where:
• J
is the motor inertia in kgm/s
Motor
• n
is the rated speed of the motor in r/min
rated
• T
is the rated torque of the motor in N⋅m.
rated
Where:
• J
is the motor inertia in kgm/s
Motor
• f
is the rated frequency of the motor in Hz.
rated
• p is the number of motor poles (not pole pairs!).
• T
is the rated torque of the motor in N⋅m.
rated
Parameter Name
Feed Forward Control Gain
parameters to a value that will easily be reached during the test (T
).
accel
Where:
• t
is the measured acceleration time in s.
accel
• f
is the rated frequency of the motor in Hz.
- 1
rated
• T
is torque limit setting during the test.
Lim_Test
• f
is the frequency reference during the test in N m.
ref_Test
Name
Online Tuning Selection
2
.
.
2
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
Setting Range
0.00 or 100.00
).
ref_Test
Setting Range
0 to 2
Default
1.00
).
Lim_Test
Default
0