R: Driveworksez Connection Parameters; Q: Driveworksez Parameters; T: Motor Tuning - YASKAWA A1000 Series Technical Manual

High performance vector control drive models: 200 v class: 0.4 to 110 kw 400 v class: 0.4 to 355 kw
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

B.3 Parameter Table
No. (Addr.)
Name
o4-12
kWh Monitor Initialization
(512H)
o4-13
Number of Run Commands
(528H)
Counter Initialization

◆ q: DriveWorksEZ Parameters

No. (Addr.)
Name
q1-01 to q6-07
(1600H to
DriveWorksEZ Parameters
1746H)

◆ r: DriveWorksEZ Connection Parameters

No. (Addr.)
Name
r1-01 to
r1-40
DriveWorksEZ Connection
(1840H to
Parameters 1 to 20 (upper/lower)
1867H)

◆ T: Motor Tuning

Enter data into the following parameters to tune the motor and drive for optimal performance
T1: Induction Motor Auto-Tuning
No. (Addr.)
Name
T1-00
Motor 1 / Motor 2 Selection
(700H)
T1-01
Auto-Tuning Mode Selection
(701H)
<37>
T1-02
Motor Rated Power
(702H)
T1-03
(703H)
Motor Rated Voltage
<18>
T1-04
Motor Rated Current
(704H)
T1-05
Motor Base Frequency
(705H)
T1-06
Number of Motor Poles
(706H)
T1-07
Motor Base Speed
(707H)
444
All Modes
0: U4-10 and U4-11 monitor data is not reset when the drive is initialized (A1-03).
1: U4-10 and U4-11 monitor data is reset when the drive is initialized (A1-03).
All Modes
0: Number of Run commands counter is not reset when the drive is initialized (A1-03).
1: Number of Run commands counter is reset when the drive is initialized (A1-03).
All Modes
Reserved for DriveWorksEZ
All Modes
DriveWorksEZ Connection Parameters 1 to 20 (upper/lower)
V/f
V/f w/PG
OLV/PM
AOLV/PM
1: Motor 1 (sets E1-
, E2-
)
2: Motor 2 (sets E3-
, E4-
)
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Rotational Auto-Tuning
1: Stationary Auto-Tuning 1
2: Stationary Auto-Tuning for Line-to-Line Resistance
3: Rotational Auto-Tuning for V/f Control (necessary for Energy Savings and Speed Estimation
Speed Search)
4: Stationary Auto-Tuning 2
8: Inertia Tuning (perform Rotational Auto-Tuning prior to Inertia Tuning)
9: ASR Gain Tuning (perform Rotational Auto-Tuning prior to ASR Gain Auto-Tuning)
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated power as specified on the motor nameplate.
Note: Use the following formula to convert horsepower into kilowatts: kW = HP x 0.746.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated voltage as specified on the motor nameplate.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated current as specified on the motor nameplate.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the rated frequency of the motor as specified on the motor nameplate.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the number of motor poles as specified on the motor nameplate.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the rated speed of the motor as specified on the motor nameplate.
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
Description
Description
Description
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Setting
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
Default: 0
TMonly
Min: 0
Max: 1
Setting
Refer to Help in the
common_
TMonly
DWEZ software.
Setting
Default: 0
common_
TMonly
Min: 0
Max: FFFFH
Setting
common_
Default: 1
TMonly
Min: 1
Max: 2
common_
TMonly
Default: 0
Min: 0
Max: 4, 8, 9
<10>
common_
Default:
<6>
TMonly
Min: 0.00 kW
Max: 650.00 kW
Default: 200.0 V
common_
TMonly
Min: 0.0 V
Max: 255.0 V
Default:
<6>
Min: 10% of drive rated
common_
TMonly
current
Max: 200% of drive
rated current
Default: 50.0 Hz
common_
TMonly
Min: 0.0 Hz
Max: 400.0 Hz
Default: 4
common_
TMonly
Min: 2
Max: 48
Default: 1450 r/min
common_
TMonly
Min: 0 r/min
Max: 24000 r/min
Page
289
289
Page
289
Page
289
Page
114
114
115
115
115
115
115
115

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents