YASKAWA A1000 Series Technical Manual page 445

High performance vector control drive models: 200 v class: 0.4 to 110 kw 400 v class: 0.4 to 355 kw
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

No. (Addr.)
Name
T1-08
PG Number of Pulses Per
(708H)
Revolution
T1-09
Motor No-Load Current
(709H)
(Stationary Auto-Tuning)
T1-10
Motor Rated Slip
(70AH)
(Stationary Auto-Tuning)
T1-11
Motor Iron Loss
(70BH)
<6> Default setting value varies by the drive model (o2-04).
<10> Default setting is determined by the control mode (A1-02).
<18> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<37> The availability of certain Auto-Tuning methods depends on the control mode selected for the drive.
<38> Default setting value differs depending on the motor code value and motor parameter settings.
T2: PM Motor Auto-Tuning
No. (Addr.)
Name
T2-01
PM Motor Auto-Tuning Mode
(750H)
Selection
T2-02
PM Motor Code Selection
(751H)
T2-03
PM Motor Type
(752H)
T2-04
PM Motor Rated Power
(730H)
T2-05
(732H)
PM Motor Rated Voltage
<18>
T2-06
PM Motor Rated Current
(733H)
T2-07
PM Motor Base Frequency
(753H)
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
V/f
V/f w/PG
OLV/PM
AOLV/PM
Set the number of pulses per revolution for the PG being used (pulse generator or encoder).
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the no-load current for the motor.
After setting the motor capacity to T1-02 and the motor rated current to T1-04, this parameter
will automatically display the no-load current for a standard 4 pole Yaskawa motor. Enter the
no-load current as indicated on the motor test report.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated slip.
After setting the motor capacity to T1-02, this parameter will automatically display the motor
slip for a standard 4 pole Yaskawa motor. Enter the motor slip as indicated on the motor test
report.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the iron loss for determining the Energy Saving coefficient.
The value is set to E2-10 (motor iron loss) set when the power is cycled. If T1-02 is changed, a
default value appropriate for the motor capacity that was entered will appear.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: PM Motor Parameter Settings
1: PM Stationary Auto-Tuning
2: PM Stationary Auto-Tuning for Stator Resistance
3: Z Pulse Offset Tuning
8: Inertia Tuning
9: ASR Gain Auto-Tuning
Prior to executing Inertia Tuning or ASR Gain Auto-Tuning, be sure to take the following steps:
• perform Auto-Tuning for motor data (T2-01 = 0, 1, or 2) or set the motor code to E5-01.
• verify all motor data entered to the drive with the motor nameplate or the motor test report.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Enter the motor code when using a Yaskawa PM motor. Once the motor code is entered, the
drive automatically sets parameters T2-03 through T2-14. When using a motor that is not
supported motor code or a non-Yaskawa motor, set FFFF here and then adjust the other T2
parameters according the motor nameplate or the motor test report.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: IPM motor
1: SPM motor. Parameter T2-17 will not be displayed with this setting.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the motor rated power.
Note: Use the following formula to convert horsepower into kilowatts: kW = HP x 0.746.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Enter the motor rated voltage as indicated on the motor nameplate.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Enter the motor rated current as indicated on the motor nameplate.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Enter the motor base frequency as indicated on the motor nameplate.
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
Default: 1024 ppr
common_
TMonly
Min: 0 ppr
116
Max: 60000 ppr
common_
TMonly
Default: –
Min: 0 A
116
Max: T1-04
common_
TMonly
Default: –
Min: 0.00 Hz
116
Max: 20.00 Hz
common_
TMonly
Default: 14 W
<38>
Min: 0 W
116
Max: 65535 W
Setting
Page
common_
TMonly
Default: 0
Min: 0
116
Max: 3, 8, 9
<10>
common_
TMonly
Default:
<16>
Min: 0000
117
Max: FFFF
common_
Default: 1
TMonly
Min: 0
117
Max: 1
common_
Default:
<6>
TMonly
Min: 0.00 kW
117
Max: 650.00 kW
Default: 200.0 V
common_
TMonly
Min: 0.0 V
117
Max: 255.0 V
Default:
<6>
Min: 10% of drive rated
common_
TMonly
current
117
Max: 200% of drive
rated current
Default: 87.5 Hz
common_
TMonly
Min: 0.0 Hz
117
Max: 400.0 Hz
B
445

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents