Compressor Application: Parameters And Settings - YASKAWA V1000 Series Installation & Start-Up Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

4.5 Application Presets
Table 4.13 Compressor Application: Parameters and Settings
No.
A1-02
b1-04
C1-01
C1-02
C6-01
E1-03
L2-01
L3-04
Table 4.14 Parameters Automatically Saved as Preferred (A2-01 to A2-16)
No.
b1-01
Frequency Reference Selection
b1-02
b1-04
C1-01
C1-02
Table 4.15 Crane Application (Hoist): Parameters and Settings
No.
A1-02
b1-01
b6-01
b6-02
C1-01
C1-02
C6-01
C6-02
d1-01
d1-02
d1-03
E1-03
H2-02
H2-03
L2-03
116
Parameter Name
Control Method Selection
Reverse Operation Selection
Acceleration Time 1
Deceleration Time 1
Duty Rating
V/f Pattern Selection
Momentary Power Loss Operation Selection
Stall Prevention Selection during Deceleration
Parameter Name
Run Command Selection
Reverse Operation Selection
Acceleration Time 1
Deceleration Time 1
Parameter Name
Control Method Selection
Frequency Reference Selection
Dwell Reference at Start
Dwell Time at Start
Acceleration Time 1
Deceleration Time 1
Duty Rating
Carrier Frequency Selection
Frequency Reference 1
Frequency Reference 2
Frequency Reference 3
V/f Pattern Selection
Terminals P1 Function Selection (open-collector)
Terminals P2 Function Selection (open-collector)
Momentary Power Loss Minimum Baseblock Time
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Optimum Setting
1: Reverse prohibited
0: Heavy Duty
No.
Parameter Name
E1-03
V/f Pattern Selection
E1-07
Mid Output Frequency (FB)
E1-08
Mid Output Frequency Voltage (VC)
E2-01
Motor Rated Current
Optimum Setting
2: Open Loop Vector Control
37: During frequency output
5: Frequency Detection 2 (FOUT)
0: V/f control
5.0 s
5.0 s
0FH
1: Enabled
1: Enabled
0: Operator
3.0 Hz
0.3 s
3.0 s
3.0 s
0: Heavy Duty
2: 5 kHz
6.0 Hz
30.0 Hz
60.0 Hz
0FH
0.3 s