No. (Addr.)
Name
U1-24
Input Pulse Monitor
(7DH)
U1-25
Software Number (Flash)
(4DH)
U1-26
Software No. (ROM)
(5BH)
<18> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<19> This value's number of decimal places depends on the drive model and the Heavy/Normal duty selection in parameter C6-01. The value will
have two decimal places (0.01 A) if the drive is set for a Maximum Applicable Motor Capacity up to 11 kW (refer to
and one decimal place (0.1 A) if the set Maximum Applicable Motor Capacity is higher than 11 kW.
<22> The display resolution depends on the rated output power of the drive after the Drive Duty has been set in parameter C6-01. Drives with a
maximum output up to 11 kW will display this value in units of 0.01 kW (two decimal places). Drives with a maximum output greater than 11
kW will display this value in units of 0.1 kW (one decimal place).
<50> When reading the value of this monitor via MEMOBUS/Modbus a value of 8192 is equal to 100% of the drive rated output current.
U2: Fault Trace
No. (Addr.)
Name
U2-01
Current Fault
(80H)
U2-02
Previous Fault
(81H)
U2-03
Frequency Reference at
(82H)
Previous Fault
U2-04
Output Frequency at Previous
(83H)
Fault
U2-05
Output Current at Previous
(84H)
Fault
U2-06
Motor Speed at Previous Fault
(85H)
U2-07
Output Voltage at Previous
(86H)
Fault
U2-08
DC Bus Voltage at Previous
(87H)
Fault
U2-09
Output Power at Previous
(88H)
Fault
U2-10
Torque Reference at Previous
(89H)
Fault
U2-11
Input Terminal Status at
(8AH)
Previous Fault
U2-12
Output Terminal Status at
(8BH)
Previous Fault
U2-13
Drive Operation Status at
(8CH)
Previous Fault
U2-14
Cumulative Operation Time at
(8DH)
Previous Fault
U2-15
Soft Starter Speed Reference at
(7E0H)
Previous Fault
U2-16
Motor q-Axis Current at
(7E1H)
Previous Fault
U2-17
Motor d-Axis Current at
(7E2H)
Previous Fault
YASKAWA ELECTRIC SIEP C710616 27C YASKAWA AC Drive A1000 Technical Manual
All Modes
Displays the frequency to pulse train input terminal RP.
All Modes
FLASH ID
All Modes
ROM ID
All Modes
Displays the current fault.
All Modes
Displays the previous fault.
All Modes
Displays the frequency reference at the previous fault.
All Modes
Displays the output frequency at the previous fault.
All Modes
Displays the output current at the previous fault.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Displays the motor speed at the previous fault.
All Modes
Displays the output voltage at the previous fault.
All Modes
Displays the DC bus voltage at the previous fault.
All Modes
Displays the output power at the previous fault.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Displays the torque reference at the previous fault.
All Modes
Displays the input terminal status at the previous fault. Displayed as in U1-10.
All Modes
Displays the output status at the previous fault. Displays the same status displayed in U1-11.
All Modes
Displays the operation status of the drive at the previous fault. Displays the same status
displayed in U1-12.
All Modes
Displays the cumulative operation time at the previous fault.
All Modes
Displays the speed reference for the soft starter at the previous fault.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Displays the q-axis current for the motor at the previous fault.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Displays the d-axis current for the motor at the previous fault.
Description
Refer to Model Number and Nameplate Check on page 29
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
B.3 Parameter Table
Analog Output
Unit
Level
common_
TMonly
Determined by H6-02
1 Hz
common_
No signal output
TMonly
available
common_
No signal output
TMonly
available
Table A.2
and
Table
for details.
Analog Output
Unit
Level
common_
No signal output
TMonly
available
common_
No signal output
TMonly
available
common_
No signal output
TMonly
0.01 Hz
available
common_
No signal output
TMonly
0.01 Hz
available
common_
No signal output
TMonly
<19> <50>
available
common_
No signal output
TMonly
0.01 Hz
available
common_
No signal output
TMonly
0.1 Vac
available
common_
No signal output
TMonly
1 Vdc
available
common_
No signal output
TMonly
0.1 kW
available
common_
No signal output
TMonly
0.1%
available
common_
No signal output
TMonly
available
common_
No signal output
TMonly
available
common_
TMonly
No signal output
available
common_
No signal output
TMonly
1 h
available
common_
No signal output
TMonly
0.01 Hz
available
common_
No signal output
TMonly
0.10%
available
common_
No signal output
TMonly
0.10%
available
Page
A.3)
Page
B
449

Hide quick links: