Wiring Network Modules; As00Scm-A; Wiring As00Scm-A - Delta AS Series Operation Manual

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

Send Quote Requests to info@automatedpt.com
4.13

Wiring Network Modules

4.13.1 AS00SCM-A

4.13.2 Wiring AS00SCM-A

4.13.2.1
COM communication mode
AS00SCM-A module has with two function card slots, CARD1 and CARD2, supporting function cards
AS-F232, AS-F422, and AS-F485. Refer to Section 4.14 for wiring.
RTU remote control mode
The card slot CARD2 supports AS-FCOPM and both CARD1 & CARD2 support AS-FEN02 and
AS-FPFN02. Refer to Section 4.14 for wiring.
4.13.2.2
COM: extension via serial ports
Switch the dip switch of the AS00SCM-A module to COM and install the module on the right side of the
AS300 series CPU module. To avoid errors, do not supply extra power to this module.
RTU remote control mode
Switch the dip switch of the AS00SCM-A module to RTU. This module uses an independent
direct-current power supply. Note the following when wiring.
(1) Keep the input cables, the output cables, and the power cable separate from one another as shown
in the following illustration. Use an independent power supply for this module.
(2) The 24 VDC cable should be twisted and connected to a module within a short distance. Do not
SCM
POWER
ERROR
CARD 1
CARD 2
ID 1
FORMAT 1
ID 2
FORMAT 2
COM.
AS00SCM-A module wiring for communication
AS00SCM-A module wiring for power
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
RTU